77840A
1.INSPECT UREA TUBE WITH HEATER ASSEMBLY (FRONT)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 25 °C (77 °F) | 1.00 to 1.24 Ω |
If the result is not as specified, replace the urea tube with heater assembly.
77840A
2.INSPECT UREA TUBE WITH HEATER ASSEMBLY (REAR)
Check that the urea tube with heater assembly (front) is normal.
When checking the urea tube with heater assembly (rear), check with the urea tube with heater assembly (front) connected.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 25 °C (77 °F) | 1.57 to 1.93 Ω |
If the result is not as specified, replace the urea injector with heater assembly.