Home › Engine / Hybrid System › N04C-WA (EMISSION CONTROL) › AMBIENT TEMPERATURE SENSOR (for Urea SCR System) › from 2019.08
RM2850E _51 Engine / Hybrid System _082614 N04C-WA EMISSION CONTROL _0403726 AMBIENT TEMPERATURE SENSOR(for Urea SCR System) G

N04C-WA EMISSION CONTROL  AMBIENT TEMPERATURE SENSOR(for Urea SCR System)  INSPECTION  


PROCEDURE

Hide 88625M 1.INSPECT COOLER THERMISTOR

a.

Measure the resistance according to the value(s) in the table below.

C287317C03
2.854,1.375 2.854,0.76 2.854,0.76 3.094,0.76 true 0.677,0.792 0.865,0.969 0.188,0.177 10 false *a 3.146,0.667 3.344,0.833 0.198,0.167 10 false *d 4.01,0.583 4.281,0.75 0.271,0.167 10 false 4.0 4.01,0.813 4.281,0.979 0.271,0.167 10 false 3.5 4.01,1.031 4.281,1.198 0.271,0.167 10 false 3.0 4.01,1.271 4.281,1.438 0.271,0.167 10 false 2.5 4.01,1.5 4.281,1.667 0.271,0.167 10 false 2.0 4.01,1.729 4.281,1.896 0.271,0.167 10 false 1.5 4.01,1.958 4.281,2.125 0.271,0.167 10 false 1.0 4.021,2.177 4.292,2.344 0.271,0.167 10 false 0.0 4.25,2.396 4.427,2.563 0.177,0.167 10 false 10 4.719,2.396 4.896,2.563 0.177,0.167 10 false 20 5.188,2.396 5.365,2.563 0.177,0.167 10 false 30 5.646,2.396 5.823,2.563 0.177,0.167 10 false 40 6.125,2.396 6.302,2.563 0.177,0.167 10 false 50 6.583,2.396 6.76,2.563 0.177,0.167 10 false 60 3.708,1.396 3.896,1.573 0.188,0.177 10 false *b 6.875,2.448 7.063,2.625 0.188,0.177 10 false *c 4.219,2.542 4.552,2.708 0.333,0.167 10 false (50) 4.677,2.542 5.01,2.708 0.333,0.167 10 false (68) 5.156,2.542 5.49,2.708 0.333,0.167 10 false (86) 5.583,2.552 6,2.719 0.417,0.167 10 false (104) 6.063,2.552 6.479,2.719 0.417,0.167 10 false (122) 6.51,2.552 6.927,2.719 0.417,0.167 10 false (140)
*a Component without harness connected
(Cooler Thermistor)
*b Resistance (kΩ)
*c Temperature (°C (°F)) *d Sensing Portion


Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.75 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



If the result is not as specified, replace the cooler thermistor.