If the battery is weak or if the engine is difficult to start, recharge the battery and perform inspections again before returning the vehicle to the customer.
1.CHECK BATTERY CONDITION
Check the battery for damage and deformation. If severe damage, deformation or leakage is found, replace the battery.
Check the volume of electrolyte in each cell.
If the electrolyte volume is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte specific gravity.
1.25 or higher at 20°C (68°F)
If the result is not as specified, recharge or replace the battery.
Measure the battery voltage.
Turn the ignition switch off and turn on the headlight for 20 to 30 seconds. This will remove the surface charge from the battery.
Measure the battery voltage between the positive (+) and negative (-) terminals of the battery.
12.3 V or higher at 20°C (68°F)
If the result is not as specified, recharge or replace the battery.
2.INSPECT BATTERY TERMINAL AND FUSE
Check that the battery terminals are not loose or corroded.
5.4 N*m (55 kgf*cm, 48 in.*lbf)
If the terminals are corroded, clean the terminals.
Measure the resistance of each fuse for the charging system.
The fuses shown in System Diagram are related to the charging system.
Below 1 Ω
If the result is not as specified, replace the fuse.
3.INSPECT DRIVE BELT
Check the belts for wear, cracks and other signs of damage.
If any defects are found, replace the drive belts as a set.
| *a | Clearance |
| *b | Correct |
| *c | Incorrect |
Check that the belt does not touch the bottom of the pulley groove.
If the result is not as specified, replace the drive belts as a set.
4.INSPECT GENERATOR WIRING
Check that the wiring is in good condition.
5.CHECK FOR ABNORMAL NOISE FROM GENERATOR
Check that the generator does not emit any abnormal noise while the engine is running.
6.INSPECT CHARGE WARNING LIGHT CIRCUIT
Turn the ignition switch to ON. Check that the charge warning light turns on.
Start the engine and check that the light turns off. If the light does not operate as specified, troubleshoot the charge warning light circuit.
7.INSPECT CHARGING CIRCUIT WITHOUT LOAD
| *1 | Generator Assembly |
| *2 | Battery |
| *a | Ammeter |
| *b | Voltmeter |
Connect a voltmeter and an ammeter to the charging circuit as follows.
If a battery/generator tester is available, connect the tester to the charging circuit in accordance with the manufacturer's instructions.
Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.
Connect the ammeter positive (+) lead to terminal B of the generator.
Connect the voltmeter positive (+) lead to terminal B of the generator.
Ground the voltmeter negative (-) lead.
Check the charging circuit.
Keep the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.
10 A or higher
13.2 to 14.8 V
If the result is not as specified, replace the generator.
If the battery is not fully charged, the ammeter reading will sometimes be more than the standard current.
8.INSPECT CHARGING CIRCUIT WITH LOAD
With the engine running at 2000 rpm, turn on the high beam headlights and turn the heater blower switch to the HI position.
Check the reading on the ammeter.
30 A or higher
If the ammeter reading is less than the standard current, replace the generator.
If the battery is fully charged, the ammeter reading will sometimes be less than the standard current.
In this case, operate the wiper motor and the window defogger to increase the load and then check the charging circuit again.