STARTER
Starter assembly Specified current 200 A or less at 11 V
Starter armature assembly Segment - Segment Standard resistance Below 1 Ω
Commutator - Armature coil core Standard resistance 10 kΩ or higher
Commutator diameter Standard diameter 36.0 mm (1.42 in.)
Minimum diameter 35.0 mm (1.38 in.)
Commutator undercut depth Standard undercut depth 0.7 mm (0.0276 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)
Commutator circle runout Minimum runout 0.05 mm (0.00197 in.)
Starter yoke assembly Terminal C - Brush Standard resistance Below 1 Ω
Brush - Starter yoke body Standard resistance 10 kΩ or higher
Starter brush Brush length Standard length 21.0 mm (0.827 in.)
Minimum length 12.0 mm (0.472 in.)
Starter brush holder assembly Positive brush holder - Negative brush holder Standard resistance 10 kΩ or higher
Starter brush spring installed load Standard spring installed load 36 N (3.6 kgf, 8.0 lbf)
Minimum spring installed load 12.4 N (1.3 kgf, 2.8 lbf)
Magnet starter switch assembly Terminal 50 - Terminal C Standard resistance Below 1.0 Ω
Terminal 50 - Magnet starter switch body Standard resistance Below 2.0 Ω

STARTER RELAY
Item Tester Connection Switch Condition Specified Condition
Starter relay assembly 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω
Battery voltage not applied to terminals 1 and 2 10 kΩ or higher

IGNITION SWITCH
Item Switch Condition Specified Condition
Between all terminals LOCK 10 kΩ or higher
4 (ACC) - 6 (AM1) ACC Below 1 Ω
4 (ACC) - 6 (AM1) ON Below 1 Ω
5 (IG1) - 6 (AM1)
11 (IG2) - 12 (AM2)
5 (IG1) - 6 (AM1) START Below 1 Ω
3 (ST1) - 6 (AM1)
11 (IG2) - 12 (AM2)
9 (ST2) - 12 (AM2)