INSPECTION
Inspection · Vehicles built from Jul 2007
| INSPECT PERSONAL LIGHT ASSEMBLY |
![]() ![]() |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
1 - 2
OFF
10 kΩ or higher
Check the light operation.
Connect the positive (+) battery lead to terminal 1 and the negative (-) battery lead to terminal 2, then check that the light illuminates.
- OK:
- Light illuminates.