2011-2016 FJ Cruiser · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built Jul 2007 – Jul 2009

Versions by build date: Jul 2007 – Jul 2009 from Aug 2009

Battery
Voltage
Standard
12.6 to 12.9 V at 20°C (68°F)
Charging circuit without load
Amperage
10A or less
Voltage
13.2 to 14.8 V
Generator
(for 100 A Type)
Generator brush holder assembly
Brush length
Standard
10.5 mm (0.413 in.)
Minimum
4.5 mm (0.177 in.)
Generator rotor assembly
Resistance
Standard
2.3 to 2.7 Ω at 20°C (68°F)
Slip ring diameter
Standard
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum
14.0 mm (0.551 in.)
Generator
(for 80 A Type)
Generator voltage regulator
Resistance
Standard
Below 1 Ω or more than 10 kΩ
Generator brush holder assembly
Brush length
Standard
10.5 mm (0.413 in.)
Minimum
4.5 mm (0.177 in.)
Generator rotor assembly
Resistance
Standard
1.7 to 2.1 Ω at 20°C (68°F)
Slip ring diameter
Standard
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum
14.0 mm (0.551 in.)
Rectifier end frame
Resistance
Standard
10 kΩ or higher
← TORQUE SPECIFICATIONS (from Aug 2009)SERVICE DATA (from Aug 2009) →