INSTALLATION
Removal / installation · Vehicles built from Aug 2009
| 1. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2) |
Temporarily install the sensor to the exhaust pipe by hand.

Using SST, tighten the sensor.

Text in Illustration *a
Fulcrum Length
- SST
- 09224-00010
- Torque:
- without SST:
- 44 N*m{ 449 kgf*cm , 32 ft.*lbf }
- with SST:
- 40 N*m{ 408 kgf*cm , 30 ft.*lbf }
- HINT:
- The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
- The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 300 mm (11.81 in.) (Click here).
- This torque value is effective when SST is parallel to the torque wrench.
- The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
Connect the sensor connector.
| 2. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2) |
Temporarily install the sensor to the exhaust pipe by hand.

Using SST, tighten the sensor.

Text in Illustration *a
Fulcrum Length
- SST
- 09224-00010
- Torque:
- without SST:
- 44 N*m{ 449 kgf*cm , 32 ft.*lbf }
- with SST:
- 40 N*m{ 408 kgf*cm , 30 ft.*lbf }
- HINT:
- The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
- The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 300 mm (11.81 in.) (Click here).
- This torque value is effective when SST is parallel to the torque wrench.
- The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
Connect the sensor connector.