Home › ENGINE › 1GR-FE ENGINE CONTROL SYSTEM › CAMSHAFT OIL CONTROL VALVE

CAMSHAFT OIL CONTROL VALVE > INSPECTION

for Preparation Click here



1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    6.9 to 7.9 Ω

    If the result is not as specified, replace the oil control valve assembly.



    A223678E02
  1. Connect the positive (+) lead of the battery to terminal 1 and the negative (-) lead to terminal 2, and check the movement of the valve.

    OK:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Battery positive (+) voltage is applied
    Valve moves in direction of left arrow shown in the illustration
    Battery positive (+) voltage is cut off
    Valve moves in direction of right arrow shown in the illustration

    If the result is not as specified, replace the oil control valve assembly.
    If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC may be output.