COMPRESSOR > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL |
![]() |
When replacing the compressor with a new one, gradually discharge the refrigerant gas from the service valve. Then drain the following amount of oil from the new compressor before installation, so that the amount of oil contained in it is the same as that in the compressor to be replaced.
| 2. INSTALL COOLER COMPRESSOR ASSEMBLY |
![]() |
Using a "TORX" socket wrench (E8), install the stud bolt.
Temporary install the cooler compressor with the 3 bolts.
Tighten the nut.
Tighten the 3 bolts.
Connect the connector.
| 3. INSTALL DISCHARGE HOSE SUB-ASSEMBLY |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL8) to a new O-ring and the fitting surface of the compressor.
Install the O-ring onto the discharge hose.
Install the discharge hose onto the compressor with the bolt.
| 4. INSTALL SUCTION HOSE SUB-ASSEMBLY |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL8) to a new O-ring and the fitting surface of the compressor.
Install the O-ring onto the suction hose.
Install the suction hose onto the compressor with the bolt.
Install the suction hose with the bolt.
| 5. INSTALL NO. 2 ENGINE WIRE |
Install the 3 bolts, nut and the No. 2 engine wire.
Close the cover to terminal 30.
Connect the clamp and No. 2 engine wire.
Install the ground wire with the bolt.
| 6. INSTALL FRONT FENDER REAR SPLASH SHIELD LH |
Install the front fender rear splash shield with the 5 clips.
| 7. INSTALL FRONT FENDER APRON SEAL LH |
Install the front fender apron seal with the 5 clips.
| 8. INSTALL FAN AND GENERATOR V BELT |
Install the fan and generator V belt (Click here).
| 9. CHARGE REFRIGERANT |

Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

Install the caps onto the service valves on the refrigerant line.
| 10. WARM UP ENGINE |
| 11. INSPECT FOR REFRIGERANT LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation as follows:
![]() |
Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.
![]() |
Bring the halogen leak detector close to the drain hose before performing the test.
If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.