DTC P043E Evaporative Emission System Reference Orifice Clog Up |
DTC P043F Evaporative Emission System Reference Orifice High Flow |
DTC P2401 Evaporative Emission Leak Detection Pump Stuck OFF |
DTC P2402 Evaporative Emission Leak Detection Pump Stuck ON |
DTC P2419 Evaporative Emission Pressure Switching Valve Stuck ON |
| DTC No. | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P043E | Reference orifice clogged | P043E, P043F, P2401, P2402, P2419 are present when one of the following conditions is met during key-off EVAP monitor
|
| While ignition switch off | 2 trips |
| P043F | Reference orifice high-flow | ||||
| P2401 | Leak detection pump stuck OFF | ||||
| P2402 | Leak detection pump stuck ON | ||||
| P2419 | Vent valve stuck closed |
| Sequence | Operation | Description | Duration |
| - | ECM activation | Activated by soak timer, 5, 7 or 9.5 hours after ignition switch turned off. | - |
| A | Atmospheric pressure measurement | Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor. | 60 seconds |
| B | First reference pressure measurement | In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 360 seconds |
| C | EVAP system pressure measurement | Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as they will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. | 15 minutes*
|
| D | Purge VSV monitor | Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second reference pressure measurement | After second reference pressure measurement, leak check performed by comparing first and second reference pressure. If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking. | 60 seconds |
| F | Final check | Atmospheric pressure measured and then monitoring result recorded by ECM. | - |

| *1 | Purge VSV: OFF (closed) | *2 | Purge VSV: ON (open) |
| *3 | Vent Valve: OFF (vent) | *4 | Vent Valve: ON (closed) |
| *5 | Leak Detection Pump: OFF | *6 | Leak Detection Pump: ON |
| *7 | Reference Orifice (0.02 inch) | *8 | Canister Pressure Sensor |
| *9 | Canister | *10 | Fuel Tank |
| *11 | Canister Pump Module | *12 | Canister Filter |
| *a | Operation A: Atmospheric Pressure Measurement | *b | Operation B, E: Reference Leak Pressure Measurement |
| *c | Operation C: EVAP System Pressure Measurement | *d | Operation D: Purge VSV Monitor |
| *e | Atmospheric Pressure | *f | Negative Pressure |

| Required Sensors/Components | Canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 7 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever these DTCs not present | None |
| Atmospheric pressure | 70 kPa(abs) [525 mmHg(abs)] or more, and less than 110 kPa(abs) [825 mmHg(abs)] |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Less than 4 km/h (2.5 mph) |
| Ignition switch | OFF |
| Time after key off | 5, 7 or 9.5 hours |
| Canister pressure sensor malfunction (P0452, P0453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of following conditions met before key off | conditions 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4°C (40°F) or more, and less than 35°C (95°F) |
| IAT | 4.4°C (40°F) or more, and less than 35°C (95°F) |
| One of following conditions met | - |
| EVAP pressure just after reference pressure measurement start | More than -0.25 kPa(gauge) [-1.88 mmHg(gauge)] |
| Reference pressure | Less than -4.85 kPa(gauge) [-36.38 mmHg(gauge)] |
| Reference pressure | -1.057 kPa(gauge) [-7.93 mmHg(gauge)] or more |
| Reference pressure | Not saturated within 360 seconds |
| Reference pressure difference between first and second | 0.9 kPa(gauge) [6.75 mmHg(gauge)] or more |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|