Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › SPIRAL CABLE

SPIRAL CABLE > INSPECTION

for Preparation Click here



1. INSPECT SPIRAL CABLE
  1. If there are any defects as mentioned below, replace the spiral cable with a new one:

    1. Scratches, cracks, dents or chips on the connector or the spiral cable.



    C128283E01
  1. Check the spiral cable.

    1. Using an ohmmeter, measure the resistance between the terminals.

      1. Turn the spiral cable 2.5 times clockwise and counterclockwise from its original position and measure the resistance at each position.
      2. Turn the spiral cable 2.5 times clockwise from its original position and measure the resistance while turning it 5 times counterclockwise.

      Standard resistance:
      Tester Connection
      Specified Condition
      A2(D+) - C1(D+)
      Below 1Ω
      A1(D-) - C2(D-)
      Below 1Ω
      B1(D2-) - C3(D2-)
      Below 1Ω
      B2(D2+) - C4(D2+)
      Below 1Ω

      NOTICE:
      To avoid breakage of the spiral cable, do not turn the spiral cable more than necessary. If the result is not as specified, replace the spiral cable.