CONDENSER > INSTALLATION |
| 1. INSTALL COOLER CONDENSER ASSEMBLY |
![]() |
Install the condenser into the vehicle.
Install the No.1 cooler condenser cushion with the 4 bolts.
| 2. INSTALL NO. 2 COOLER CONDENSER CUSHION RH |
![]() |
Install the cooler condenser cushion with the 2 bolts and nut.
| 3. INSTALL NO. 2 COOLER CONDENSER CUSHION LH |
![]() |
Install the cooler condenser cushion with the 2 bolts.
| 4. INSTALL COOLER BRACKET |
![]() |
Install the cooler bracket with the nut.
Engage the clamp.
| 5. INSTALL AIR CONDITIONING TUBE ASSEMBLY |
![]() |
Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring onto the air conditioning tube.
Install the tube onto the condenser with the bolt.
| 6. INSTALL DISCHARGE HOSE SUB-ASSEMBLY |
![]() |
Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.
Apply sufficient compressor oil to a new O-ring and the fitting surface of the hose joint.
Install the O-ring onto the discharge hose.
Install the discharge hose onto the condenser with the bolt.
| 7. INSTALL FRONT BUMPER COVER |
Install the 4 clips.
Engage the 2 claws and install the front bumper cover.
![]() |
Install the 8 screws and the 4 bolts.
Install the 5 clips.
Remove the protective tape.
| 8. INSTALL RADIATOR GRILLE |
Engage the 5 clips and install the radiator grille.
Install the 2 screws.
Install the 2 clips.
| 9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 10. CHARGE REFRIGERANT |

Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

Install the caps onto the service valves on the refrigerant line.
| 11. WARM UP ENGINE |
| 12. CHECK FOR REFRIGERANT LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation as follows:
![]() |
Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.
![]() |
Bring the halogen leak detector close to the drain hose before performing the test.
If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.