AIR CONDITIONING PANEL > INSPECTION |
| 1. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY |
![]() |
Check the blower switch resistance.
Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table below.
| Tester connection | Blower Switch Position | Specified Condition |
| 1 - 4 - 5 - 6 - 8 | OFF | 10 KΩ or higher |
| 1 - 8 | LO | Below 1 Ω |
| 1 - 6 - 8 | M1 | Below 1 Ω |
| 1 - 5 - 8 | M2 | Below 1 Ω |
| 1 - 4 - 8 | HI | Below 1 Ω |
![]() |
Inspect the illumination operation.
Connect the positive (+) lead from the battery to terminals 1 (IG+) and 2 (ILL+) and the negative (-) lead to terminal 20 (GND), then check that the illuminations light up.
![]() |
Inspect the A/C indicator operation.
Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminals 8 (BLW) and 20 (GND).
Push the A/C button in and then check that the indicator lights up.
| Switch Condition | Specified Condition |
| Switch ON | Indicator illuminates |
| Switch OFF | Indicator turns off |
![]() |
Under the above condition, connect the positive (+) lead from the battery to terminal 2 (ILL+) and then check that the indicator dims.
| Switch Condition | Specified Condition |
| Switch ON | Indicator dims |
| Switch OFF | Indicator turns off |
![]() |
Inspect the REC indicator operation.
Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminal 20 (GND).
Push the REC button in and check that the indicator lights up.
| Switch Condition | Specified Condition |
| Switch ON | Indicator illuminates |
| Switch OFF | Indicator turns off |
![]() |
Under the above condition, connect the positive (+) lead from the battery to terminal 2 (ILL+) and then check that the indicator dims.
| Switch Condition | Specified Condition |
| Switch ON | Indicator dims |
| Switch OFF | Indicator turns off |
![]() |
Inspect the temperature control switch operation.
Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminals 8 (BLW) and 20 (GND).
Check the A/C indicator and REC indicator operations when the temperature switch is operated.
| Temperature Switch Condition | Specified Condition (A/C indicator and REC indicator) |
| Except MAX A/C | Neither indicator illuminates |
| MAX A/C | Both indicators illuminate*1 |
![]() |
Inspect MODE switch operation.
Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminal 20 (GND).
Check the REC indicator operation when the MODE switch is operated.
| Condition | Specified Condition (REC indicator) |
| MODE switch except DEF REC switch ON ←→ OFF | Indicator turns ON ←→ OFF in accordance with REC switch operation |
| MODE switch DEF REC switch ON ←→ OFF | Indicator turns off |