1.INSPECT FUSE (IGN FUSE)
B175681E01
  1. Remove the IGN fuse.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    IGN fuse
    Always
    Below 1 Ω

    1. Reinstall the IGN fuse.



NG
CHECK FOR SHORTS IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
OK


2.INSPECT FUSE (ECU-B FUSE)
B175117E02
  1. Remove the ECU-B fuse.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    ECU-B fuse
    Always
    Below 1 Ω

    1. Reinstall the ECU-B fuse.



NG
CHECK FOR SHORTS IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
OK


3.CHECK HARNESS AND CONNECTOR (TRANSPONDER KEY ECU - BATTERY)


    B164266E29
  1. Disconnect the E79 transponder key ECU connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E79-1 (+B) - Body ground
    Always
    11 to 14 V
    E79-2 (IG) - Body ground
    Ignition switch OFF
    Below 1 V
    Ignition switch ON
    11 to 14 V

  1. Reconnect the transponder key ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (TRANSPONDER KEY ECU - BODY GROUND)


    B164266E30
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E79-16 (GND) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)