Home › BODY ELECTRICAL › OTHER SYSTEM › INVERTER RELAY

INVERTER RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT INVERTER RELAY


E109076E04
  1. Check the resistance.

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard Resistance:
      Tester Connection
      Specified Condition
      3 - 5
      10 kΩ or higher
      3 - 5
      Below 1 Ω
      (Battery voltage applied to terminals 1 and 2)

      If the result is not as specified, replace the inverter relay.