Home › BODY ELECTRICAL › LIGHTING › LIGHTING SYSTEM

LIGHTING SYSTEM > Interior Light Auto Cut Circuit

for Preparation Click here


DESCRIPTION

When battery saving control operates while the interior lights are on, the main body ECU opens the DOME relay to turn off the lights.

WIRING DIAGRAM


E260855E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Main Body / Active Test.

  1. Check that the relay operates.

    Main Body 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Doom Relay Cut
    DOME Relay
    OFF/ON
    -

    OK:
    Dome relay operates.



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT DOME RELAY
  1. Remove the DOME relay from the No. 2 engine room relay block.



    E222294E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Voltage is applied between terminals 1 and 2
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (DOME Relay)

  1. Reinstall the DOME relay



NG
REPLACE DOME RELAY
OK


3.CHECK HARNESS AND CONNECTOR (BATTERY - DOME RELAY)
  1. Remove the DOME relay from the No. 2 engine room relay block.



    E260847E04
  1. Measure the voltage according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 2 - Body ground
    Always
    11 to 14 V
    Relay terminal 5 - Body ground
    Always
    11 to 14 V

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block
    *2
    DOME Relay Holder

  1. Reinstall the DOME relay



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (DOME RELAY - MAIN BODY ECU)
  1. Remove the DOME relay from the No. 2 engine room relay block.

  1. Disconnect the E6 main body ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 1 - E6-3 (LMRY)
    Always
    Below 1 Ω
    Relay terminal 1 - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the DOME relay.

  1. Reconnect the main body ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU