Home › ENGINE › 1GR-FE CHARGING › GENERATOR

GENERATOR > INSPECTION

for Preparation Click here



1. INSPECT GENERATOR CLUTCH PULLEY


    A222451
  1. Hold the center of the generator clutch pulley and check that the outer ring turns counterclockwise and does not turn clockwise.
    Text in Illustration 
    V100135
    Free
    V100136
    Lock
    If the result is not as specified, replace the generator clutch pulley.



2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY


    A128079E05
  1. Using a vernier caliper, measure the brush length.
    Text in Illustration 
    *a
    Length

    Standard exposed length:
    9.5 to 11.5 mm (0.374 to 0.453 in.)

    Minimum exposed length:
    4.5 mm (0.177 in.)

    If the brush length is less than the minimum, replace the generator brush holder assembly.



3. INSPECT GENERATOR ROTOR ASSEMBLY


    A079306E02
  1. Check that the generator rotor bearing is not rough or worn.
    If necessary, replace the generator rotor assembly.



    B012264E24
  1. Check the generator rotor for an open circuit.

    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Slip Ring

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip Ring - Slip Ring
      20°C (68°F)
      2.3 to 2.7 Ω

      If the result is not as specified, replace the generator rotor assembly.



    B012265E19
  1. Check if the generator rotor is grounded.

    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Slip Ring
      *2
      Rotor Core

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip Ring - Rotor Core
      Always
      10 MΩ or higher

      If the result is not as specified, replace the generator rotor assembly.



    A124106E05
  1. Using a vernier caliper, measure the slip ring diameter.
    Text in Illustration 
    *a
    Diameter

    Standard diameter:
    14.2 to 14.4 mm (0.559 to 0.567 in.)

    Minimum diameter:
    14.0 mm (0.551 in.)

    If the diameter is less than the minimum, replace the generator rotor assembly.



4. INSPECT GENERATOR DRIVE END FRAME BEARING


    A128080
  1. Check that the drive end frame bearing is not rough or worn.
    If necessary, replace the generator drive end frame bearing.