Home › DRIVE LINE · VF4B TRANSFER › TRANSFER INDICATOR SWITCH

TRANSFER INDICATOR SWITCH > INSPECTION

for Preparation Click here



1. INSPECT TRANSFER INDICATOR SWITCH (for Center Differential Lock Position)


G034535
  1. Measure the resistance of the switch.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 2
    Pushed
    Below 1 Ω
    1 - 2
    Not pushed
    10 kΩ or higher

    If the result is not as specified, replace the switch.



2. INSPECT TRANSFER INDICATOR SWITCH (for LL Position)


G034535
  1. Measure the resistance of the switch.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 2
    Pushed
    Below 1 Ω
    1 - 2
    Not pushed
    10 kΩ or higher

    If the result is not as specified, replace the switch.