Home › BODY ELECTRICAL › HORN › HORN RELAY

HORN RELAY > INSPECTION

for Preparation Click here



1. INSPECT HORN RELAY


    B130568E01
  1. Check the resistance.

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      3 - 5
      10 kΩ or higher
      Below 1 Ω
      (Battery voltage applied to terminals 1 and 2)

      If the result is not as specified, replace the horn relay.