Home › BODY ELECTRICAL › DOOR LOCK › FRONT DOOR LOCK

FRONT DOOR LOCK > INSPECTION

for Preparation Click here



1. INSPECT FRONT DOOR LOCK LH


    B132175E01
  1. Check the operation.

    1. Apply battery voltage to the front door lock and check the operation of the front door lock motor.

      Standard:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 2
      Locks
      Battery positive (+) → Terminal 2
      Battery negative (-) → Terminal 4
      Unlocks

      If the result is not as specified, replace the front door lock.

  1. Check the resistance of the unlock detection switch.

    1. Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Door Lock Condition
      Specified Condition
      7 - 8
      Locked
      10 kΩ or higher
      7 - 8
      Unlocked
      Below 1 Ω

      If the result is not as specified, replace the front door lock.



    B132176E01
  1. Check the resistance of the door lock and unlock switch.

    1. Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Door Lock Condition
      Specified Condition
      7 - 9
      Locked
      Below 1 Ω
      7 - 9
      Unlocked
      10 kΩ or higher
      7 - 10
      Locked
      10 kΩ or higher
      7 - 10
      Unlocked
      Below 1 Ω

      If the result is not as specified, replace the front door lock.



2. INSPECT FRONT DOOR LOCK RH


    B118058E01
  1. Check the operation.

    1. Apply battery voltage to the front door lock and check the operation of the front door lock motor.

      Standard:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 3
      Battery negative (-) → Terminal 1
      Locks
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 3
      Unlocks

      If the result is not as specified, replace the front door lock.

  1. Check the resistance of the unlock detection switch.

    1. Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Door Lock Condition
      Specified Condition
      7 - 8
      Locked
      10 kΩ or higher
      7 - 8
      Unlocked
      Below 1 Ω

      If the result is not as specified, replace the front door lock.



    B132177E01
  1. Check the resistance of door lock and unlock switch.

    1. Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Door Lock Condition
      Specified Condition
      6 - 8
      Locked
      Below 1 Ω
      6 - 8
      Unlocked
      10 kΩ or higher
      5 - 8
      Locked
      10 kΩ or higher
      5 - 8
      Unlocked
      Below 1 Ω