Home › ENGINE › 1GR-FE EMISSION CONTROL › CANISTER

CANISTER > INSPECTION

for Preparation Click here



1. INSPECT CHARCOAL CANISTER ASSEMBLY


    A282087
  1. Visually check the charcoal canister assembly.

    1. Visually check the charcoal canister assembly for cracks or damage.
      If cracks or damage are found, replace the charcoal canister assembly.



    A282088E01
  1. Check charcoal canister assembly operation.

    1. With the purge port closed, blow 5 kPa (0.05 kgf/cm2, 0.7 psi) of air into the vent port, and check that air flows from the air inlet port.
      Text in Illustration 
      *1
      Vent Port
      *2
      Air Inlet Port
      *3
      Purge Port
      *a
      Air
      If the result is not as specified, replace the charcoal canister assembly.



    2. A282089E01
    3. With the vent port closed, blow 5 kPa (0.05 kgf*cm2, 0.7 psi) of air into the air inlet port, and check that air flows from the purge port.
      Text in Illustration 
      *1
      Vent Port
      *2
      Air Inlet Port
      *3
      Purge Port
      *a
      Air
      If the result is not as specified, replace the charcoal canister assembly.



    A282090E01
  1. Check for air leaks.

    1. Connect a pressure gauge to the vent port of the charcoal canister.
      Text in Illustration 
      *1
      Vent Port
      *2
      Air Inlet Port
      *3
      Purge Port
      *4
      Pressure Gauge

    2. With the purge port and the air inlet port closed, apply 20 kPa (150 mmHg, 5.91 in.Hg) of pressurized air into the vent port, then confirm that pressure is retained for 1 minute.
      If the result is not as specified, replace the charcoal canister assembly.



    A259847E01
  1. Check the leak detection pump sub-assembly.

    1. Check that air flows from port A to port B.
      Text in Illustration 
      *a
      Air
      *b
      Port A
      *c
      Port B
      If the result is not as specified, leak detection pump sub-assembly.



    2. A259848E01
    3. Connect the positive (+) lead of the battery to terminal 5 and the negative (-) lead to terminal 1.
      Text in Illustration 
      *a
      Component without harness connected
      (Leak Detection Pump Sub-assembly)

    4. Check that the valve is closed.
      If the result is not as specified, replace the charcoal canister leak detection pump sub-assembly.