Home › BODY ELECTRICAL › OTHER SYSTEM › INVERTER MAIN SWITCH

INVERTER MAIN SWITCH > INSPECTION

for Preparation Click here



1. INSPECT INVERTER MAIN SWITCH


    E064419E02
  1. Check the resistance.
    Text in Illustration 
    *a
    Component without harness connected
    (Inverter Main Switch)

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Switch operation):
      Tester Connection
      Switch Condition
      Specified Condition
      4 (B) - 3 (E)
      Main switch OFF
      10 kΩ or higher
      4 (B) - 3 (E)
      Main switch ON
      Below 1 Ω

      If the result is not as specified, replace the inverter main switch.



    E064419E03
  1. Check the illumination operation.
    Text in Illustration 
    *a
    Component without harness connected
    (Inverter Main Switch)

    1. Apply battery voltage between the terminals of the switch, and check the illumination condition of the inverter main switch.

      OK (Indicator circuit):
      Measurement conditions
      Switch Condition
      Specified Condition
      Battery positive (+) → Terminal 6 (IND)
      Battery negative (-) → Terminal 3 (E)
      Main switch ON
      Illuminates
      Battery positive (+) → Terminal 6 (IND)
      Battery negative (-) → Terminal 3 (E)
      Main switch OFF
      Does not illuminate

      If the result is not as specified, replace the inverter main switch.

      OK (Illumination circuit):
      Measurement conditions
      Switch Condition
      Specified Condition
      Battery positive (+) → Terminal 1 (ILL+)
      Battery negative (-) → Terminal 2 (ILL-)
      Always
      Illuminates

      If the result is not as specified, replace the inverter main switch.