Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1GR-FE CHARGING

1GR-FE CHARGING > SERVICE DATA



Battery
Standard specific gravity
1.25 to 1.29 at 20°C (68°F)
Charging circuit without load
Standard current
10 A or less
Standard voltage
13.2 to 14.8 V
(when engine speed at 2000 rpm)
Charging circuit with load
Standard current
30 A or higher
Generator brush holder
Standard exposed length
9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length
4.5 mm (0.177 in.)
Generator rotor
Standard resistance
Slip ring - Slip ring
2.3 to 2.7 Ω
Slip ring - Rotor core
10 MΩ or higher
Standard diameter
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter
14.0 mm (0.551 in.)