AIR FUEL RATIO SENSOR > INSPECTION |
| 1. INSPECT AIR FUEL RATIO SENSOR (w/ Secondary Air Injection System) |
![]() |
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected (Air Fuel Ratio Sensor) |
| *b | for Bank 1 |
| *c | for Bank 2 |
| Tester Connection | Condition | Specified Condition |
| 1 (HA1A) - 2 (+B) | 20°C (68°F) | 1.6 to 3.2 Ω |
| 1 (HA1A) - 4 (A1A-) | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| 1 (HA2A) - 2 (+B) | 20°C (68°F) | 1.6 to 3.2 Ω |
| 1 (HA2A) - 4 (A2A-) | Always | 10 kΩ or higher |
| 2. INSPECT AIR FUEL RATIO SENSOR (w/o Secondary Air Injection System) |
![]() |
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected: (Air Fuel Ratio Sensor) |
| *b | for Bank 1: |
| *c | for Bank 2: |
| Tester Connection | Condition | Specified Condition |
| 1 (HA1A) - 2 (+B) | 20°C (68°F) | 1.8 to 3.4 Ω |
| 1 (HA1A) - 4 (A1A-) | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| 1 (HA2A) - 2 (+B) | 20°C (68°F) | 1.8 to 3.4 Ω |
| 1 (HA2A) - 4 (A2A-) | Always | 10 kΩ or higher |