Home › ENGINE › 1GR-FE ENGINE CONTROL SYSTEM › AIR FUEL RATIO SENSOR

AIR FUEL RATIO SENSOR > INSPECTION

for Preparation Click here



1. INSPECT AIR FUEL RATIO SENSOR (w/ Secondary Air Injection System)


    A171118E01
  1. Measure the resistance according to the value(s) in the table below.
    Text in Illustration 
    *a
    Component without harness connected
    (Air Fuel Ratio Sensor)
    *b
    for Bank 1
    *c
    for Bank 2

    Standard Resistance (for Bank 1):
    Tester Connection
    Condition
    Specified Condition
    1 (HA1A) - 2 (+B)
    20°C (68°F)
    1.6 to 3.2 Ω
    1 (HA1A) - 4 (A1A-)
    Always
    10 kΩ or higher

    Standard Resistance (for Bank 2):
    Tester Connection
    Condition
    Specified Condition
    1 (HA2A) - 2 (+B)
    20°C (68°F)
    1.6 to 3.2 Ω
    1 (HA2A) - 4 (A2A-)
    Always
    10 kΩ or higher

    If the result is not as specified, replace the air fuel ratio sensor.