Home › ENGINE › 1GR-FE ENGINE CONTROL SYSTEM › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


    A159234E15
  1. Measure the resistance according to the value(s) in the table below.
    Text in Illustration 
    *a
    Component without harness connected:
    (Heated Oxygen Sensor)
    *b
    for Bank 1:
    *c
    for Bank 2:

    Standard Resistance (for Bank 1):
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    Always
    10 kΩ or higher

    Standard Resistance (for Bank 2):
    Tester Connection
    Condition
    Specified Condition
    1 (HT2B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT2B) - 4 (E2)
    Always
    10 kΩ or higher

    If the result is not as specified, replace the sensor.