COMMON RAIL > INSPECTION |
| 1. COMMON RAIL ASSEMBLY |
Inspect the fuel pressure sensor
![]() |
Measure the resistance according to the value(s) in the table below.
| Terminals | Resistance |
| 2(PR) - Body | Below 3k Ω |
| 1(E2) - 2(PR) | Below 16.4kΩ |
Inspect the pressure discharge valve resistance.
![]() |
Measure the resistance between the terminals.