THERMOSTAT > INSPECTION |
| 1. THERMOSTAT |
![]() |
![]() |
Immerse the thermostat in water and gradually heat the water.
Check the valve opening temperature.
![]() |
Check the valve lift.
Check that the valve is fully closed when the thermostat is at low temperature (below 40 °C (104 °F)).
If not closed, replace the thermostat.