Home › ENGINE ยท 2TR-FE › COOLING › THERMOSTAT

THERMOSTAT > INSPECTION

for Preparation Click here



1. THERMOSTAT

HINT:
A088651
The valve opening temperature is provided on the thermostat.



    P000436
  1. Immerse the thermostat in water and gradually heat the water.

  1. Check the valve opening temperature.

    Valve opening temperature:
    80 to 84 °C (176 to 183 °F)

    If the valve opening temperature is not as specified, replace the thermostat.



    A103360
  1. Check the valve lift.

    Valve lift:
    10 mm (0.394 in.) or more at 95 °C (203 °F)

    If the valve lift is not as specified, replace the thermostat.

  1. Check that the valve is fully closed when the thermostat is at low temperature (below 40 °C (104 °F)).
    If not closed, replace the thermostat.