Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM > TERMINALS OF ECU

for Preparation Click here



CHECK AIR CONDITIONING AMPLIFIER (2TR-FE, 2KD-FTV)

E103734E01


Symbols (Terminal No.)
Wiring Color
Tester Description
Condition
Specification
PTC (H18-2) - GND (H18-29)
LG - W-B
PTC heater control signal
Ignition switch: ON
Temperature switch: Max. HOT
Coolant temperature: Below 76°C (169°F)
Ambient temperature: Below 10°C (50°F)
PTC heater: Not operate → Operate (ALT, F-DUTY more than 95 %)
Below 1.0 V → 10 to 14 V
PTCL (H18-3) - GND (H18-29)
GR - W-B
PTC heater permission signal
Ignition switch: ON
Temperature switch: Max. HOT
Coolant temperature: Below 73°C (163°F)
Ambient temperature: Below 10°C (50°F)
PTC heater: Not operate → Operate (ALT, F-DUTY more than 95 %)
Below 1.0 V → 10 to 14 V
PHTR (H18-5) - GND (H18-29)
L-W - W-B
Idle-up switch signal
Ignition switch: ON
Idle-up switch: OFF → ON
Below 1.0 V → 10 to 14 V
A.C (H18-8) - GND (H18-29)
Y - W-B
A/C switch signal
Ignition switch: ON
Blower switch: ON
A/C switch: OFF → ON
Below 1.0 V → 10 to 14 V
LED+ (H18-9) - GND (H18-29)
G-B - W-B
A/C switch indicator signal
Ignition switch: ON
Blower switch: ON
A/C switch: OFF → ON
Below 1.0 V → 10 to 14 V
BLW (H18-16) - GND (H18-29)
L - W-B
Blower motor control signal
Ignition switch: ON
Blower switch: OFF → ON
10 to 14 V → Below 1.0 V
GND (H18-29) - Body ground
W-B - Body ground
Ground for main power supply
Always
Below 1.0 Ω
PRE (H18-4) - GND (H18-29)
R-L - W-B
A/C pressure sensor signal
Start engine
Operate A/C system
Refrigerant pressure: Abnormal pressure (More than 3,030 kPa (31.0 kgf/cm, 440 psi))
4.7 V or higher
PRE (H18-4) - GND (H18-29)
R-L - W-B
A/C pressure sensor signal
Start engine
Operate A/C system
Refrigerant pressure: Abnormal pressure (less than 180 kPa (1.9 kgf/cm, 27 psi))
Below 0.7 V
PRE (H18-4) - GND (H18-29)
R-L - W-B
A/C pressure sensor signal
Start engine
Operate A/C system
Refrigerant pressure: Normal pressure (less than 3,030 kPa (31.0 kgf/cm, 440 psi) and more than 180 kPa (1.9 kgf/cm, 27 psi))
0.7 to 4.7 V
S5 (H18-13) - SG-1 (H13-12)
Y-R - L-W
Power supply for pressure sensor
Ignition switch: LOCK → ON
Below 1.0 V → 5.15 V
TAM (H18-25) - SG-1 (H13-12)
G-W - L-W
A/C ambient temperature sensor signal
Ignition switch: LOCK → ON
Click here
SG-1 (H18-12) - Body ground
L-W - Body ground
Ground for each sensor
Always
Below 1.0 Ω
TE (H18-24) - SG (H18-31)
W - L-B
A/C evaporator temperature sensor signal
Ignition switch: LOCK → ON
Click here
SG (H18-31) - Body ground
L-B - Body ground
Ground for each sensor
Always
Below 1.0 Ω
FRBV (H18-22) - SG (H18-31)
L-R - LG-B
Room compartment temperature set signal
Max. HOT → Max. COOL
0 Ω → 3 kΩ
MHSW (H18-38) - Body ground
B-W - Body ground
Max. hot switch signal
Except max. HOT → Max. HOT
Below 1.0 V → 10 to 14 V
CANH (H18-10) - Body ground
L - Body ground
CAN communication system
Ignition switch: LOCK → ON
Pulse generation
CANH (H18-11) - Body ground
W - Body ground
CAN communication system
Ignition switch: LOCK → ON
Pulse generation
RRTE (H18-23) - SG-2 (H18-30)
W-R - L-B
Rear A/C evaporator temperature sensor signal
Ignition switch: LOCK → ON
Click here
SG-2 (H18-30) - Body ground
L-B - Body ground
Ground for rear A/C evaporator temperature sensor
Always
Below 1.0 Ω
RRAC (H18-7) - Body ground
P - Body ground
Rear A/C switch signal
Ignition switch: ON
A/C switch: OFF → ON
Below 1.0 V → 10 to 14 V
RMGV (H18-18) - Body ground
R-Y - Body ground
Rear magnetic valve signal
Ignition switch: ON
Rear magnetic valve: OFF → ON
10 to 14 V → Below 1.0 V
LOCK (H18-28) - SG (H18-31)
L - L-B
Compressor lock sensor signal
Engine idling
A/C switch: ON (Magnet clutch: ON)
Pulse generation
(see waveform 1)
MGC (H18-19) - Body ground
R - Body ground
Magnet clutch ON permission signal
Ignition switch: ON
A/C switch: OFF → ON
10 to 14 V → Below 1.0 V
IG+ (H18-20) - Body ground
R-B - Body ground
Power source (IG)
Ignition switch: LOCK or ACC → ON
Below 1.0 V → 10 to 14 V
B (H18-40) - Body ground
W-R - Body ground
Power source (Back-up)
Always
10 to 14 V

CHECK AIR CONDITIONING AMPLIFIER (5L-E)

E109942E01


Symbols (Terminal No.)
Wiring Color
Tester Description
Condition
Specification
AC1 (H19-8) - Body ground
R-B - Body ground
Compressor operation signal
Ignition switch: ON
A/C switch: OFF → ON
3.7 to 4.5 V → 1.3 to 2.6 V
ACT (H19-10) - Body ground
G-W - Body ground
Compressor permission signal
Ignition switch: ON
A/C switch: OFF → ON
Below 1.0 V → 10 to 14 V
A.C (H19-11) - GND (H19-6)
Y - W-B
A/C switch signal
Ignition switch: ON
A/C switch: OFF → ON
Below 1.0 V → 10 to 14 V
GND (H19-6) - Body ground
W-B - Body ground
Ground for main power supply
Always
Below 1.0 Ω
PRE (H19-3) - Body ground
R-L - Body ground
A/C pressure switch signal
Start engine
Operate A/C system
Refrigerant pressure: Normally → Less than 0.19 MPa (2.0 kgf/cm, 28 psi) or more than 1.34 MPa (13.7 kgf/cm, 195 psi))
Below 1 V → 10 to 14 V
TE (H19-4) - SG (H19-16)
W - L-B
A/C evaporator temperature sensor signal
Ignition switch: LOCK → ON
Click here
SG (H19-16) - Body ground
L-B - Body ground
Ground for each sensor
Always
Below 1.0 Ω
FRBV (H19-12) - SG (H19-16)
B - L-B
Room compartment temperature set signal
Max. HOT → Max. COOL
0 Ω → 3 Ω
RRTE (H19-7) - SG (H19-16)
W-R - L-B
Rear A/C evaporator temperature sensor signal
Ignition switch: LOCK → ON
Click here
RRAC (H19-18) - Body ground
Y - Body ground
Rear A/C switch signal
Ignition switch: ON
A/C switch: OFF → ON
Below 1.0 V → 10 to 14 V
RMGV (H19-9) - Body ground
R-Y - Body ground
Rear magnetic valve signal
Ignition switch: ON
Rear magnetic valve: OFF → ON
Below 1.0 V → 10 to 14 V
MGC (H19-15) - Body ground
R - Body ground
Magnet clutch ON permission signal
Ignition switch: ON
A/C switch: OFF → ON
Below 1.0 V → 10 to 14 V
IG+ (H19-13) - Body ground
R-B - Body ground
Power source (IG)
Ignition switch: LOCK or ACC → ON
Below 1.0 V → 10 to 14 V


    I031459E02
  1. Waveform 1:
    Measure the waveform between terminal LOCK of the A/C amplifier assembly connector and body ground.

    OK:
    A waveform should be output as shown in the illustration.