Home › BRAKE › BRAKE › 5L VACUUM PUMP

5L VACUUM PUMP > ON-VEHICLE INSPECTION

for Preparation Click here



1. OPERATION CHECK
  1. Disconnect the vacuum hose.

  1. Connect the vacuum gauge to the vacuum pump.

  1. Start the engine.



    C106115E01
  1. Measure the vacuum with the engine idling.

    Standard:
    More than 650 mmHg (86.7 kPa).