WIPER SWITCH > INSPECTION |
| 1. INSPECT WIPER SWITCH (LHD) |
![]() |
Continuity Check
Measure the resistance according to the value(s) in the table below.
| Switch position | Tester connection | Specified condition |
| MIST | 17 (+B) - 7 (+1) | Below 1 Ω |
| OFF | 16 (+S) - 7 (+1) | Below 1 Ω |
| INT | 16 (+S) - 7 (+1) | Below 1 Ω |
| LO | 17 (+B) - 7 (+1) | Below 1 Ω |
| HI | 17 (+B) - 8 (+2) | Below 1 Ω |
| Switch position | Tester connection | Specified condition |
| OFF | 2 (E) - 11 (WF) | 10 kΩ or higher |
| ON | 2 (E) - 11 (WF) | Below 1 Ω |
| Switch position | Tester connection | Specified condition |
| WASH | 2 (E) - 12 (WR) | Below 1 Ω |
| OFF | 2 (E) - 13 (C1R) 2 (E) - 12 (WR) 2 (E) - 10 (+1R) | 10 kΩ or higher |
| INT | 2 (E) - 13 (C1R) | Below 1 Ω |
| ON | 2 (E) - 10 (+1R) | Below 1 Ω |
| ON + WASH | 2 (E) - 12 (WR) 2 (E) - 10 (+1R) | Below 1 Ω |
Intermittent Operation Check
Connect the voltmeter (+) terminal to terminal 7 (+1) and the voltmeter (-) terminal to terminal 2 (E).
Connect the battery's positive (+) lead to terminal 17 (+B), and connect the battery's negative (-) lead to terminals 2 (E) and 16 (+S).
Turn the wiper switch to the INT position.
Connect the battery's positive (+) lead to terminal 16 (+S) for 5 seconds.
Connect the battery's negative (-) lead to terminal 16 (+S) to operate the intermittent wiper relay. Measure the voltage between terminals 7 (+1) and 2 (E).

![]() |
Front Washer Operation Check
Turn the wiper switch to the OFF position.
Connect the battery's positive (+) lead to terminal 17 (+B), connect the battery's negative (-) to terminals 16 (+S) and 2 (E).
Connect the voltmeter (+) terminal to terminal 7 (+1) and the voltmeter (-) terminal to terminal 2 (E). Measure the voltage between terminals 7 (+1) and 2 (E) when turning the washer switch ON and OFF respectively.
| 2. INSPECT WIPER SWITCH (RHD) |
![]() |
Continuity Check
Measure the resistance according to the value(s) in the table below.
| Switch position | Tester connection | Specified condition |
| MIST | 11 (+B) - 3 (+1) | Below 1 Ω |
| OFF | 12 (+S) - 3 (+1) | Below 1 Ω |
| INT | 12 (+S) - 3 (+1) | Below 1 Ω |
| LO | 11 (+B) - 3 (+1) | Below 1 Ω |
| HI | 11 (+B) - 2 (+2) | Below 1 Ω |
| Switch position | Tester connection | Specified condition |
| OFF | 8 (E) - 17 (WF) | 10 kΩ or higher |
| ON | 8 (E) - 17 (WF) | Below 1 Ω |
| Switch position | Tester connection | Specified condition |
| Washer | 8 (E) - 16 (WR) | Below 1 Ω |
| OFF | 8 (E) - 15 (C1R) 8 (E) - 16 (WR) 8 (E) - 18 (+1R) | 10 kΩ or higher |
| INT | 8 (E) - 15 (C1R) | Below 1 Ω |
| ON | 8 (E) - 18 (+1R) | Below 1 Ω |
| On + Washer | 8 (E) - 16 (WR) 8 (E) - 18 (+1R) | Below 1 Ω |
Intermittent Operation Check
Connect the voltmeter (+) terminal to terminal 3 (+1) and the voltmeter (-) terminal to terminal 8 (E).
Connect the battery's positive (+) lead to terminal 11 (+B), and connect the battery's negative (-) lead to terminals 8 (E) and 12 (+S).
Turn the wiper switch to the INT position.
Connect the battery's positive (+) lead to terminal 12 (+S) for 5 seconds.
Connect the battery's negative (-) lead to terminal 12 (+S) to operate the intermittent wiper relay. Measure the voltage between terminals 3 (+1) and 8 (E).

![]() |
Front Washer Operation Check
Turn the wiper switch to the OFF position.
Connect the battery's positive (+) lead to terminal 11 (+B), and connect the battery's negative (-) to terminals 12 (+S) and 8 (E).
Connect the voltmeter (+) terminal to terminal 3 (+) and the voltmeter (-) terminal to terminal 8 (E). Measure the voltage between terminals 3 (+1) and 8 (E) when turning the washer switch ON and OFF respectively.