DTC P0100 Mass or Volume Air Flow Circuit |
DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Conditions | Trouble Areas |
| P0100 | Mass Air Flow (MAF) meter voltage less than 0.2 V, or more than 4.9 V for 3 seconds |
|
| P0102 | Mass Air Flow (MAF) meter voltage less than 0.2 V, for 3 seconds |
|
| P0103 | Mass Air Flow (MAF) meter more than 4.9 V for 3 seconds |
|
| Mass Air Flow Rate (g/s) | Malfunctions |
| Approximately 0.0 |
|
| 271.0 or more |
|

| 1.READ VALUE OF INTELLIGENT TESTER (MASS AIR FLOW RATE) |
Connect an intelligent tester to the DLC3.
Start the engine.
Turn the tester ON.
Select the following menu items: Powertrain / Engine and ECT / Data List / MAF.
Read the values displayed on the tester.
| Mass Air Flow Rate (g/s) | Proceed To |
| 0.0 | A |
| 271.0 or more | B |
| Between 1.0 and 270.0 (*1) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT MASS AIR FLOW METER (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the A3 Mass Air Flow (MAF) meter connector.
Turn the ignition switch to the ON position.
Measure the voltage between the terminal of the wire harness side connector and body ground.
| Tester Connections | Specified Conditions |
| +B (A3-1) - Body ground | 9 to 14 V |
Reconnect the MAF meter connector.
|
| ||||
| OK | |
| 3.INSPECT ECM (VG VOLTAGE) |
![]() |
Start the engine.
Measure the voltage between the terminals of the ECM connector.
| Tester Connections | Conditions | Specified Conditions |
| VG (D3-28) - E2G (D3-30) | Engine idling | 0.5 to 3.0 V |
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the A3 MAF meter connector.
Disconnect the D3 ECM connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| VG (A3-3) - VG (D3-28) | Below 1 Ω |
| E2G (A3-2) - E2G (D3-30) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| VG (A3-3) or VG (D3-28) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - INTEGRATION RELAY) |
Remove the integration relay (MAIN relay) from the engine room R/B No.1.
![]() |
Disconnect the A3 MAF meter connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| +B (A3-1) - integration relay (B4) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| +B (A3-1) or integration relay (B4) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reinstall the integration relay (MAIN relay).
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the A3 MAF meter connector.
Disconnect the D3 ECM connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| VG (A3-3) - VG (D3-28) | Below 1 Ω |
| E2G (A3-2) - E2G (D3-30) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| VG (A3-3) or VG (D3-28) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 7.INSPECT ECM (SENSOR GROUND) |
![]() |
Measure the resistance.
| Tester Connections | Specified Conditions |
| E2G (D3-30) - Body ground | Below 1 Ω |
|
| ||||
| OK | ||
| ||