Home › ENGINE ยท 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM (w/ Secondary Air Injection System)

DTC    P0110    Intake Air Temperature Circuit

DTC    P0112    Intake Air Temperature Circuit Low Input

DTC    P0113    Intake Air Temperature Circuit High Input

for Preparation Click here


DESCRIPTION

The Intake Air Temperature (IAT) sensor, mounted on the Mass Air Flow (MAF) meter, monitors the IAT. The IAT sensor has a built in thermistor with a resistance that varies according to the temperature of the intake air. When the IAT is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Figure 1).
The IAT sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.
Resistor R and the IAT sensor are connected in series. When the resistance value of the IAT sensor changes, according to changes in the IAT, the voltage at terminal THA also varies. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve drivability.
A056276E06

HINT:
When any of DTCs P0110, P0112 and P0113 are set, the ECM enters fail-safe mode. During fail-safe mode, the IAT is estimated to be 20°C (68°F) by the ECM. Fail-safe mode continues until a pass condition is detected.


DTC No.
Proceed To
DTC Detection Conditions
Trouble Areas
P0110
Step 1
Open or short in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds
(1 trip detection logic)
  1. Open or short in IAT sensor circuit
  2. IAT sensor (built into MAF meter)
  3. ECM
P0112
Step 4
Short in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds
(1 trip detection logic)
  1. Short in IAT sensor circuit
  2. IAT sensor (built into MAF meter)
  3. ECM
P0113
Step 2
Open in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds
(1 trip detection logic)
  1. Open in IAT sensor circuit
  2. IAT sensor (built into MAF meter)
  3. ECM

HINT:
When any of these DTCs are set, check the Intake Air Temperature (IAT) by selecting the following menu items on an intelligent tester: Powertrain / Engine and ECT / Data List / Intake Air.


Temperature Displayed
Malfunctions
-40°C (-40°F)
Open circuit
140°C (284°F) or higher
Short circuit

MONITOR DESCRIPTION

The ECM monitors the sensor voltage and uses this value to calculate the IAT. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the IAT sensor and sets a DTC.
Example:
If the sensor voltage output is -40°C (-40°F) for 0.5 seconds or more, the ECM determines that there is an open in the IAT sensor circuit, and sets DTC P0113. Conversely, if the voltage output is more than 140°C (284°F) for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit, and sets DTC P0112.
If the malfunction is not repaired successfully, a DTC is set 0.5 seconds after the engine is next started.

WIRING DIAGRAM


A111657E01


INSPECTION PROCEDURE

HINT:
  1. If other DTCs relating to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
  2. Read freeze frame data using an intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.READ VALUE OF INTELLIGENT TESTER (INTAKE AIR TEMPERATURE)
  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    Same as actual Intake Air Temperature (IAT).


    Result:

    Temperature Displayed
    Proceed To
    -40°C (-40°F)
    A
    140°C (284°F) or higher
    B
    Same as actual IAT
    C

    HINT:
    1. If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
    2. If there is a short circuit, the intelligent tester indicates 140°C (284°F) or higher.



B
Go to step 4

C
CHECK FOR INTERMITTENT PROBLEMS
A


2.READ VALUE OF INTELLIGENT TESTER (CHECK FOR OPEN IN HARNESS)
  1. Confirm good connection of the connector to the Mass Air Flow (MAF) meter.



    A109989E01
  1. Disconnect the A3 Mass Air Flow (MAF) meter connector.

  1. Connect terminals THA and E2 of the MAF meter wire harness side connector.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ETC / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    140°C (284°F) or higher

  1. Reconnect the MAF meter connector.



OK
REPLACE MASS AIR FLOW METER
NG


3.READ VALUE OF INTELLIGENT TESTER (CHECK FOR OPEN IN ECM)
  1. Confirm good connection of the connectors to the ECM.



    A109990E01
  1. Disconnect the A3 MAF meter connector.

  1. Connect terminals THA and E2 of the ECM connectors.

    HINT:
    Before checking, perform visual and contact pressure checks on the ECM connector.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    140°C (284°F) or higher

  1. Reconnect the MAF meter connector.



NG
REPLACE ECM
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

4.READ VALUE OF INTELLIGENT TESTER (CHECK FOR SHORT IN HARNESS)


    A084869E09
  1. Disconnect the A3 MAF meter connector.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    -40°C (-40°F)

  1. Reconnect the MAF meter connector.



OK
REPLACE MASS AIR FLOW METER
NG


5.READ VALUE OF INTELLIGENT TESTER (CHECK FOR SHORT IN ECM)


    A109991E01
  1. Disconnect the D1 and D3 ECM connectors.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position.

  1. Turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Intake Air.

  1. Read the value displayed on the tester.

    Standard:
    -40°C (-40°F)

  1. Reconnect the ECM connector.



NG
REPLACE ECM
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR