DTC    13    Engine Speed Sensor Circuit Malfunction (NE Circuit)

for Preparation Click here


DESCRIPTION

The engine speed sensor in the Engine Control System contains a signal plate and a pickup coil for NE signal. The NE signal plate has 56 teeth and is mounted in the injection pump. The NE signal sensor generates 56 signals for every 2 engine revolutions. The ECM detects the engine speed and cam lift position of the injection pump. The ECM uses TDC signal and NE signals for injection timing control. And NE signal is used for injection volume control, also.

DTC No.
DTC Detection Condition
Trouble Area
13
No NE signal to ECM for 0.5 sec. or more at 680 rpm or more
  1. Open or short in engine speed sensor circuit
  2. Engine speed sensor
  3. ECM
No NE signal to ECM for 2.0 sec. or more during cranking

WIRING DIAGRAM


A110553E01


INSPECTION PROCEDURE

1.INSPECT ENGINE SPEED SENSOR


    A105092E01
  1. Check the engine speed sensor installation.

  1. Disconnect the engine speed sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    205 to 255 Ω (20°C (68°F))

    HINT:
    The engine speed sensor is integrated with the injection pump assembly. If the engine speed sensor is replaced, the injection pump assembly must be replaced in whole.



NG
CHECK AND REPLACE INJECTION PUMP ASSEMBLY
OK


2.CHECK ECM


    A106823E01
  1. Connect the engine speed sensor connector.

  1. While cranking or idling, measure the waveform according to the value(s) in the table below.

    OK:
    Tester Connection
    Specified Condition
    NE+ (D2-19) - NE- (D2-18)
    Correct waveform shown
    TDC+ (D2-17) - TDC- (D2-16)
    Correct waveform shown



NG
Go to step 3
OK

REPLACE ECM 

3.CHECK HARNESS AND CONNECTOR (ECM - ENGINE SPEED SENSOR)


    A106825E01
  1. Disconnect the engine speed sensor connector.

  1. Disconnect the ECM D2 connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    NE+ (D18-2) - NE+ (D2-19)
    Below 1 Ω
    NE- (D18-1) - NE- (D2-18)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    NE+ (D2-19)- NE- (D2-18)
    10 kΩ or higher
    NE+ (D2-19) - Body ground
    10 kΩ or higher
    NE- (D2-18) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK FOR INTERMITTENT PROBLEMS