Home › ENGINE · 5L-E › ENGINE CONTROL SYSTEM › ECD SYSTEM

DTC    35    Manifold Absolute Pressure / Barometric Pressure Circuit Malfunction

for Preparation Click here


DESCRIPTION

The manifold absolute pressure sensor generates voltage by the vacuum value as shown in the illustration. This voltage of the manifold absolute pressure sensor is one of the factors to decide the injection volume and injection timing.
A006532E02

DTC No.
DTC Detection Condition
Trouble Area
35
Open or short in manifold absolute pressure sensor circuit for 2 sec. or more
  1. Open or short in manifold absolute pressure sensor circuit
  2. Manifold absolute pressure sensor
  3. ECM

WIRING DIAGRAM


A110560E01


INSPECTION PROCEDURE

HINT:
  1. If different DTCs that are related to different systems are output simultaneously while terminal E2 is used as a ground terminal, terminal E2 may be open.
  2. Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.


When using intelligent tester:

1.READ VALUE OF INTELLIGENT TESTER (INTAKE MANIFOLD PRESSURE)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch ON.

  1. Select the item "Powertrain/Engine and ECT/Data List/PIM" and read its value displayed on the intelligent tester.

    OK:
    The same as atmospheric pressure.

    HINT:
    When DTC 35 is present, check the manifold absolute pressure by selecting "Powertrain/Engine and ECT/ Data List/PIM" on the intelligent tester.


    Intake Manifold Pressure (kPa)
    Malfunction
    Approx. 0
    1. Short in PIM circuit
    192 or more
    1. Open or short in VC circuit
    2. Open in PIM circuit
    3. Open in E2 circuit



NG
Go to step 3
OK


2.CHECK CONNECTION OF VACUUM HOSE
  1. Check that the vacuum hose is securely connected and no leaks from the connection.

    OK:
    The vacuum hose is securely connected and there are no leaks from the connection.



NG
REPAIR OR REPLACE VACUUM HOSE
OK

CHECK FOR INTERMITTENT PROBLEMS 

3.INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR


NG
REPLACE MANIFOLD ABSOLUTE PRESSURE SENSOR
OK


4.INSPECT ECM (CHECK VOLTAGE)


    A062416E08
  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    VC (D4-1) - E2 (D4-9)
    4.5 to 5.5 V



NG
REPLACE ECM
OK


5.INSPECT ECM (CHECK VOLTAGE)


    A062416E09
  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    PIM (D4-2) - E2 (D4-9)
    1.0 to 2.2 V



NG
Go to step 6
OK

REPLACE ECM 

6.CHECK HARNESS AND CONNECTOR (ECM - MANIFOLD ABSOLUTE PRESSURE SENSOR)


    A110538E01
  1. Disconnect the manifold absolute pressure sensor connector.

  1. Disconnect the ECM D4 connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    VC (D57-3) - VC (D4-1)
    Below 1 Ω
    PIM (D57-2) - PIM (D4-2)
    Below 1 Ω
    E (D57-1) - E2 (D4-9)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    VC (D4-1) - PIM (D4-2)
    10 kΩ or higher
    VC (D4-1) - E2 (D4-9)
    10 kΩ or higher
    PIM (D4-2) - E2 (D4-9)
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK FOR INTERMITTENT PROBLEMS 


When not using intelligent tester:

1.INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR


NG
REPLACE MANIFOLD ABSOLUTE PRESSURE SENSOR
OK


2.INSPECT ECM (CHECK VOLTAGE)


    A062416E08
  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    VC (D4-1) - E2 (D4-9)
    4.5 to 5.5 V



NG
REPLACE ECM
OK


3.INSPECT ECM (CHECK VOLTAGE)


    A062416E09
  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    PIM (D4-2) - E2 (D4-9)
    1.0 to 2.2 V



NG
Go to step 4
OK

REPLACE ECM 

4.CHECK HARNESS AND CONNECTOR (ECM - MANIFOLD ABSOLUTE PRESSURE SENSOR)


    A110538E01
  1. Disconnect the manifold absolute pressure sensor connector.

  1. Disconnect the ECM D4 connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    VC (D57-3) - VC (D4-1)
    Below 1 Ω
    PIM (D57-2) - PIM (D4-2)
    Below 1 Ω
    E (D57-1) - E2 (D4-9)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    VC (D4-1) - PIM (D4-2)
    10 kΩ or higher
    VC (D4-1) - E2 (D4-9)
    10 kΩ or higher
    PIM (D4-2) - E2 (D4-9)
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK FOR INTERMITTENT PROBLEMS