Home › ENGINE · 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM (w/ Secondary Air Injection System)

DTC    P0420    Catalyst System Efficiency Below Threshold (Bank 1)

for Preparation Click here


MONITOR DESCRIPTION

The ECM uses sensors mounted in front of and behind the Three-Way Catalytic Converter (TWC) to monitor its efficiency.
The first sensor, the Air-Fuel Ratio (A/F) sensor, sends pre-catalyst information to the ECM. The second sensor, the Heated Oxygen (HO2) sensor, sends post-catalyst information to the ECM.
In order to detect any deterioration in the TWC, the ECM calculates the Oxygen Storage Capacity (OSC) of the TWC. This calculation is based on the voltage output of the HO2 sensor while performing active air-fuel ratio control, rather than the conventional detecting method, which uses the locus ratio.
The OSC value is an indication of the oxygen storage capacity of the TWC. When the vehicle is being driven with a warm engine, active air-fuel ratio control is performed for approximately 15 to 20 seconds. When it is performed, the ECM deliberately sets the air-fuel ratio to lean or rich levels. If a rich-lean cycle of the HO2 sensor is long, the OSC becomes greater. There is a direct correlation between the OSCs of the HO2 sensor and the TWC.
The ECM uses the OSC value to determine the state of the TWC. If any deterioration has occurred, it illuminates the MIL and sets a DTC.

DTC No.
DTC Detection Conditions
Trouble Areas
P0420
OSC value smaller than standard value under active air-fuel ratio Control
(2 trip detection logic)
  1. Front exhaust pipe
  2. Gas leakage from exhaust system
  3. Air-Fuel Ratio (A/F) sensor (sensor 1)
  4. Heated Oxygen (HO2) sensor (sensor 2)

CONFIRMATION DRIVING PATTERN

HINT:
Perform the operation with the engine speeds and time durations described below prior to checking the waveforms of the A/F and HO2 sensors. This is in order to activate the sensors sufficiently to obtain the appropriate inspection results.


A093766E09

1. Connect the intelligent tester to the DLC3 (1).
2. Start the engine and warm it up with all the accessories switched OFF, until the engine coolant temperature stabilizes (2).
3. Run the engine at an engine speed of between 2,500 rpm and 3,000 rpm for at least 3 minutes (3).
4. While running the engine at 3,000 rpm for 2 seconds and 2,000 rpm for 2 seconds, check the waveforms of the A/F and HO2 sensors using the tester or scan too (4)l.

HINT:
  1. If either of the voltage outputs of the Air-Fuel Ratio (A/F) or Heated Oxygen (HO2) sensor does not fluctuate, or either of the sensors makes a noise, the sensor may be malfunctioning.
  2. If the voltage outputs of both the sensors remain lean or rich, the air-fuel ratio may be extremely lean or rich. In such cases, perform the following A/F control using an intelligent tester.
  3. If the Three-Way Catalytic Converter (TWC) has deteriorated, the HO2 sensor (located behind the TWC) voltage output fluctuates up and down frequently, even under normal driving conditions (active air-fuel control is not performed).


A076893E01

HINT:
When using an intelligent tester only:

Malfunctioning areas can be identified by performing the A/F Control function provided in the Active Test. The A/F Control function can help to determine whether the Air-Fuel Ratio (A/F) sensor, Heated Oxygen (HO2) sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the A/F Control operation using an intelligent tester.

CONDITIONING FOR SENSOR TESTING

HINT:
When using an intelligent tester only:

Malfunctioning areas can be identified by performing the A/F Control function provided in the Active Test. The A/F Control function can help to determine whether the Air-Fuel Ratio (A/F) sensor, Heated Oxygen (HO2) sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the A/F Control operation using an intelligent tester.
  1. Connect an intelligent tester to the DLC3.
  2. Start the engine and turn the tester ON.
  3. Warm up the engine at an engine speed of 2,500 rpm for approximately 90 seconds.
  4. On the tester, select the following menu items: Powertrain / Engine and ECT / Active Test / A/F Control.
  5. Perform the A/F Control operation with the engine in an idling condition.
  6. Monitor the voltage outputs of the A/F and HO2 sensors (AFS B1S1 and OS2 B1S2) displayed on the tester.

HINT:
  1. The A/F Control operation lowers the fuel injection volume by 12.5 % or increases the injection volume by 25 %.
  2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.


Voltage:

Tester Display
(Sensor)
Injection Volumes
Status
Voltages
AFS B1S1
(A/F)
+25 %
Rich
Less than 3.0
AFS B1S1
(A/F)
-12.5 %
Lean
More than 3.35
O2S B1S2
(HO2)
+25 %
Rich
More than 0.5
O2S B1S2
(HO2)
-12.5 %
Lean
Less than 0.4

CAUTION:
The Air-Fuel Ratio (A/F) sensor has an output delay of a few seconds and the Heated Oxygen (HO2) sensor has a maximum output delay of approximately 20 seconds.


Case
A/F Sensor (Sensor 1)
Output Voltage
HO2 Sensor (Sensor 2)
Output Voltage
Mainly Suspected
Trouble Areas
1
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
-
Output voltage
More than 3.35 V
Less than 3.0 V
A104056
Output voltage
More than 0.5 V
Less than 0.4 V
A104057
2
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. A/F sensor
  2. A/F sensor heater
  3. A/F sensor circuit
Output voltage
Almost no reaction
A103185
Output voltage
More than 0.5 V
Less than 0.4 V
A104057
3
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. HO2 sensor
  2. HO2 sensor heater
  3. HO2 sensor circuit
Output voltage
More than 3.35 V
Less than 3.0 V
A104056
Output voltage
Almost no reaction
A103185
4
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. Injector
  2. Fuel pressure
  3. Gas leakage from exhaust system
(Air-fuel ratio extremely lean or rich)
Output voltage
Almost no reaction
A103185
Output voltage
Almost no reaction
A103185
  1. Following the A/F CONTROL procedure enables technicians to check and graph the voltage outputs of both the A/F and HO2 sensors.
  2. To display the graph, select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / A/F Control / User Data / AFS B1S1 and O2S B1S2.

INSPECTION PROCEDURE

HINT:
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0420)
  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position and turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / DTC.

  1. Read DTCs.

    Result:

    Display (DTC Output)
    Proceed To
    P0420
    A
    P0420 and other DTCs
    B

    HINT:
    If any DTCs other than P0420 are output, troubleshoot those DTCs first.



B
GO TO DTC CHART
A


2.PERFORM ACTIVE TEST BY INTELLIGENT TESTER (A/F CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine and turn the tester ON.

  1. Warm up the engine at an engine speed of 2,500 rpm for approximately 90 seconds.

  1. On the tester, select the following menu items: Powertrain / Engine and ECT / Active Test / A/F Control.

  1. Perform the A/F Control operation with the engine in an idling condition.

  1. Monitor the voltage outputs of the A/F and HO2 sensors (AFS B1S1 and O2S B1S2) displayed on the tester.

    HINT:
    1. The A/F Control operation lowers the fuel injection volume by 12.5 % or increases the injection volume by 25 %.
    2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.


    Voltage:

    Tester Display
    (Sensor)
    Injection Volumes
    Status
    Voltages
    AFS B1S1
    (A/F)
    +25 %
    Rich
    Less than 3.0
    AFS B1S1
    (A/F)
    -12.5 %
    Lean
    More than 3.35
    O2S B1S2
    (HO2)
    +25 %
    Rich
    More than 0.5
    O2S B1S2
    (HO2)
    -12.5 %
    Lean
    Less than 0.4


    Result:

    Status
    AFS B1S1
    Status
    O2S B1S2
    A/F Condition and A/F and HO2 Sensors Condition
    Misfires
    Main Suspected Trouble Areas
    Proceed To
    Lean/Rich
    Lean/Rich
    Normal
    -
    1. Three-Way Catalytic Converter (TWC)
    2. Gas leakage from exhaust system
    A
    Lean
    Lean/Rich
    A/F sensor malfunction
    -
    1. A/F sensor malfunction
    B
    Rich
    Lean/Rich
    A/F sensor malfunction
    -
    1. A/F sensor malfunction
    B
    Lean/Rich
    Lean
    HO2 sensor malfunction
    -
    1. HO2 sensor
    2. Gas leakage from exhaust system
    C
    Lean/Rich
    Rich
    HO2 sensor malfunction
    -
    1. HO2 sensor
    2. Gas leakage from exhaust system
    C
    Lean
    Lean
    Actual air-fuel ratio lean
    May occur
    1. Extremely rich or lean actual air-fuel ratio
    2. Gas leakage from exhaust system
    A
    Rich
    Rich
    Actual air-fuel ratio lean
    -
    1. Extremely rich or lean actual air-fuel ratio
    2. Gas leakage from exhaust system
    A

    Lean: During A/F Control, the A/F sensor output voltage (AFS) is consistently more than 3.35 V, and the HO2 sensor output voltage (O2S) is consistently less than 0.4 V.
    Rich: During A/F Control, the AFS is consistently less than 3.0 V, and the O2S is consistently more than 0.5 V.
    Lean/Rich: During A/F Control of the ACTIVE TEST, the output voltage of the HO2 sensor alternates correctly.



B
CHECK AND REPLACE AIR FUEL RATIO SENSOR

C
Go to step 4
A


3.CHECK FOR EXHAUST GAS LEAKAGE

OK:
No gas leakage.

NOTICE:
Replace both the front and rear catalysts (front exhaust pipe).



NG
REPAIR OR REPLACE EXHAUST GAS LEAKAGE POINT
OK

REPLACE THREE-WAY CATALYTIC CONVERTER 

4.INSPECT HEATED OXYGEN SENSOR


    A058685E01
  1. Disconnect the D35 Heated Oxygen (HO2) sensor connector.

  1. Measure the resistance between the terminals of the HO2 sensor connector.

    Resistance:
    Tester Connections
    Specified Conditions
    HT1B (1) - +B (2)
    11 to 16 Ω at 20°C (68°F)
    HT1B (1) - E2 (4)
    10 kΩ or higher

  1. Reconnect the HO2 sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR
OK

REPAIR OR REPLACE EXHAUST GAS LEAKAGE POINT