CANISTER > INSPECTION |
| 1. INSPECT CHARCOAL CANISTER ASSEMBLY |
Check the appearance.
![]() |
Visually check the charcoal canister for cracks or damage.
If necessary, replace the charcoal canister.
Check the charcoal canister filter.
![]() |
Remove the charcoal canister filter.
![]() |
Visually check that the charcoal canister filter is not excessively damaged or dirty.
If necessary, replace the charcoal canister.
Check the ventilation.
![]() |
Blow air (4.7 kPa (48 gf/cm2, 0.68 psi)) into port A, then check that the air flows from ports B and C.
If the ventilation is not as specified, replace the charcoal canister.
Clean the filter in canister.
![]() |
Clean the filter by blowing (19.6 kpa (0.2 kgf/cm2, 2.8 psi)) compressed air into port B while holding port A closed.
Install the charcoal canister filter.