CONDENSER > INSTALLATION |
| 1. INSTALL W/ RECEIVER CONDENSER ASSEMBLY |
![]() |
Install the w/ receiver condenser assembly with the 4 bolts.
| 2. INSTALL COOLER REFRIGERANT LIQUID PIPE A |
Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser assembly.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring on the cooler refrigerant liquid pipe A.
![]() |
Install the cooler refrigerant liquid pipe A on the cooler condenser assembly with the bolt.
![]() |
Install the clamp with the bolt.
| 3. INSTALL COOLER REFRIGERANT DISCHARGE PIPE A |
Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser assembly.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring on the cooler refrigerant discharge pipe A.
![]() |
Install the cooler refrigerant discharge pipe A on the cooler condenser assembly with the bolt.
| 4. INSTALL FRONT BUMPER REINFORCEMENT |
![]() |
Install the front bumper reinforcement with the 6 bolts.
| 5. INSTALL FRONT FLOOR CROSS MEMBER REINFORCEMENT SUB-ASSEMBLY |
![]() |
Install the front floor cross member reinforcement sub-assembly with the 5bolts.
| 6. INSTALL HOOD LOCK SUPPORT BRACE SUB-ASSEMBLY |
![]() |
Install the hood lock support brace sub-assembly with the 3 bolts.
| 7. INSTALL FRONT BUMPER |
| 8. INSTALL STEP PLATE COVER RH |
| 9. INSTALL STEP PLATE COVER LH |
| 10. INSTALL RADIATOR GRILLE |
| 11. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge with refrigerant HFC-134a (R134a).

| 12. WARM UP ENGINE |
Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging refrigerant.
| 13. CHECK FOR LEAKAGE OF REFRIGERANT |
After recharging refrigerant gas, check for leakage of refrigerant gas using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a gas leak detector, check for leakage of the refrigerant line.
![]() |
Bring the gas leak detector close to the drain hose with the detector's power off.
If a gas leak is not detected on the drain hose, remove the blower motor control from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.