REAR COOLING UNIT > INSTALLATION |
| 1. INSTALL REAR COOLING UNIT |
![]() |
Install the rear cooling unit with the 5 bolts.
Connect the connector.
| 2. INSTALL AIR CONDITIONING TUBE AND ACCESSORY ASSEMBLY |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL 8) to a new O-ring and the fitting surface of the rear cooling unit.
Install the O-ring onto the air conditioning tube and accessory assembly.
![]() |
Install the air conditioning tube and accessory assembly onto the rear cooling unit with the 2 bolts.
| 3. INSTALL COOLER REFRIGERANT HOSE NO.1 INSULATOR |
![]() |
Install the cooler refrigerant hose No.1 insulator.
| 4. INSTALL COOLER UNIT NO.3 DRAIN HOSE |
![]() |
Install the cooler unit No.3 drain hose.
| 5. INSTALL COOLER UNIT NO.2 DRAIN HOSE |
Install the cooler unit No.2 drain hose.
| 6. REMOVE ROOF NO.1 HEADLINING (for Full-trim) |
| 7. REMOVE ROOF NO.1 HEADLINING (for Semi-trim) |
| 8. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge with refrigerant HFC-134a (R134a).

| 9. WARM UP ENGINE |
Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging refrigerant.
| 10. CHECK FOR LEAKAGE OF REFRIGERANT |
After recharging refrigerant gas, check for leakage of refrigerant gas using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a gas leak detector, check for leakage of the refrigerant line.
![]() |
Bring the gas leak detector close to the drain hose with the detector's power off.
If a gas leak is not detected on the drain hose, remove the blower motor control from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.