DTC P0351/14 Ignition Coil "A" Primary / Secondary Circuit |
DTC P0352/15 Ignition Coil "B" Primary / Secondary Circuit |
DTC P0353/14 Ignition Coil "C" Primary / Secondary Circuit |
DTC P0354/15 Ignition Coil "D" Primary / Secondary Circuit |

| DTC No. | DTC Detection Conditions | Trouble Areas |
| P0351/14 P0352/15 P0353/14 P0354/15 | No IGF signal to ECM while engine running (1 trip detection logic) |
|

| Items | Contents |
| Terminals | CH1: IGT1, IGT2, IGT3, IGT4 - E1 CH:2 IGF1 - E1 |
| Equipment Settings | 2 V/Division, 20 ms/Division |
| Conditions | Cranking or idling |


| 1.CHECK WHETHER DTC OUTPUT RECURS (DTC P0351/14, P0352/15, P0353/14 OR P0354/15) |
Connect an intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester ON.
Clear DTCs (Click here).
Shuffle the ignition coils with igniters (among No.1 to No.4 cylinders).
Perform a simulation test.
Check DTCs displayed on the tester.
| Display (DTC Output) | Proceed To |
| Same DTC output | A |
| Other ignition coil DTC output | B |
|
| ||||
| A | |
| 2.INSPECT ECM (IGT1, IGT2, IGT3, IGT4 AND IGF1 SIGNAL) |
![]() |
Inspect the ECM using an oscilloscope.
While cranking or idling, check the waveform between the terminals of the D1 ECM connector.
| Tester Connections | Specified Conditions |
| IGT1 (D1-17) - E1 (D1-3) | Correct waveform shown in the illustration appears |
| IGT2 (D1-16) - E1 (D1-3) | Correct waveform shown in the illustration appears |
| IGT3 (D1-15) - E1 (D1-3) | Correct waveform shown in the illustration appears |
| IGT4 (D1-14) - E1 (D1-3) | Correct waveform shown in the illustration appears |
| IGF1 (D1-23) - E1 (D1-3) | Correct waveform shown in the illustration appears |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM) |
![]() |
Disconnect the ignition coil with igniter connector.
Disconnect the D1 ECM connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| IGF (D20-2) - IGF1 (D1-23) | Below 1 Ω |
| IGF (D21-2) - IGF1 (D1-23) | Below 1 Ω |
| IGF (D22-2) - IGF1 (D1-23) | Below 1 Ω |
| IGF (D23-2) - IGF1 (D1-23) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| IGT1 (D20-3) - IGT1 (D1-17) | Below 1 Ω |
| IGT2 (D21-3) - IGT2 (D1-16) | Below 1 Ω |
| IGT3 (D22-3) - IGT3 (D1-15) | Below 1 Ω |
| IGT4 (D23-3) - IGT4 (D1-14) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| IGF (D20-2) or IGF1 (D1-23) - Body ground | 10 kΩ or higher |
| IGF (D21-2) or IGF1 (D1-23) - Body ground | 10 kΩ or higher |
| IGF (D22-2) or IGF1 (D1-23) - Body ground | 10 kΩ or higher |
| IGF (D23-2) or IGF1 (D1-23) - Body ground | 10 kΩ or higher |
| Tester Connections | Specified Conditions |
| IGT1 (D20-3) or IGT1 (D1-17) - Body ground | 10 kΩ or higher |
| IGT2 (D21-3) or IGT2 (D1-16) - Body ground | 10 kΩ or higher |
| IGT3 (D22-3) or IGT3 (D1-15) - Body ground | 10 kΩ or higher |
| IGT4 (D23-3) or IGT4 (D1-14) - Body ground | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the ignition coil with igniter connector.
|
| ||||
| OK | |
| 4.INSPECT IGNITION COIL ASSEMBLY (POWER SOURCE) |
![]() |
Disconnect the ignition coil with igniter connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| GND (D20-4) - Body ground | Below 1 Ω |
| GND (D21-4) - Body ground | Below 1 Ω |
| GND (D22-4) - Body ground | Below 1 Ω |
| GND (D23-4) - Body ground | Below 1 Ω |
Turn the ignition switch to the ON position.
Measure the voltage between the terminals of the wire harness side connector.
| Tester Connections | Specified Conditions |
| +B (D20-1) - GND (D20-4) | 9 to 14 V |
| +B (D21-1) - GND (D21-4) | 9 to 14 V |
| +B (D22-1) - GND (D22-4) | 9 to 14 V |
| +B (D23-1) - GND (D23-4) | 9 to 14 V |
Reconnect the ignition coil with igniter connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - IGNITION SWITCH) |
![]() |
Disconnect the ignition coil with igniter connector.
Disconnect the H25 ignition switch connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| +B (D20-1) - IG2 (H25-6) | Below 1 Ω |
| +B (D21-1) - IG2 (H25-6) | Below 1 Ω |
| +B (D22-1) - IG2 (H25-6) | Below 1 Ω |
| +B (D23-1) - IG2 (H25-6) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| +B (D20-1) or IG2 (H25-6) - Body ground | 10 kΩ or higher |
| +B (D21-1) or IG2 (H25-6) - Body ground | 10 kΩ or higher |
| +B (D22-1) or IG2 (H25-6) - Body ground | 10 kΩ or higher |
| +B (D23-1) or IG2 (H25-6) - Body ground | 10 kΩ or higher |
Reconnect the ignition coil with igniter connector.
Reconnect the ignition switch connector.
|
| ||||
| OK | ||
| ||