ECD SYSTEM > MIL Circuit |

| 1.CHECK MIL |
![]() |
Turn the ignition switch ON.
| MIL Condition | Proceed |
| MIL is illuminated | A |
| MIL is not illuminated | B |
|
| ||||
| A | |
| 2.CLEAR DTC |
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and push the intelligent tester main switch on.
Read the DTC (Click here).
Clear the DTC (Click here).
Check that MIL is not illuminated.
|
| ||||
| OK | ||
| ||
| 3.CHECK WIRE HARNESS (FOR SHORT IN WIRE CIRCUIT) |
![]() |
Disconnect the B10 ECM connector.
Turn the ignition switch ON.
Check that MIL is not illuminated.
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER) |
![]() |
Disconnect the ECM B10 connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified condition |
| W (B10-5) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.INSPECT ECM (CHECK VOLTAGE) |
![]() |
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Specified condition |
| W (B10-5) - Body ground | 9 to 14 V |
|
| ||||
| OK | ||
| ||
| 6.INSPECT COMBINATION METER (CHECK VOLTAGE) |
![]() |
Disconnect the combination meter connector.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Specified condition |
| EGW (H20-32) - Body ground | 9 to 14 V |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER) |
![]() |
Disconnect the combination meter connector.
Disconnect the ECM B10 connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified condition |
| EGW (H20-32) - W (B10-5) | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 8.INSPECT COMBINATION METER (CHECK VOLTAGE) |
![]() |
Disconnect the combination meter connector.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Specified condition |
| IG+ (H20-6) - Body ground | 9 to 14 V |
|
| ||||
| OK | ||
| ||
| 9.CHECK FUSE (MET IGN FUSE) |
![]() |
Remove the MET IGN fuse from the instrument panel J/B.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| MET IGN fuse | Below 1 Ω (Continuity) |
|
| ||||
| OK | |
| 10.CHECK HARNESS AND CONNECTOR (COMBINATION METER - MET IGN FUSE) |
![]() |
Disconnect the combination meter connectors.
Remove the MET IGN fuse from the instrument panel J/B.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified condition |
| (MET IGN fuse terminal 1 of J/B) - IG+ (H20-6) | Below 1 Ω |
|
| ||||
| OK | ||
| ||