Home › ENGINE · 5L-E › ENGINE CONTROL SYSTEM › ECD SYSTEM

ECD SYSTEM > Pre-heating Control Circuit

for Preparation Click here


DESCRIPTION

When the ignition switch turns ON, the ECM calculates the glow indicator lighting time/heating corresponding to the coolant temperature at that time and turns on the glow indicator light/glow plug relay.
As the ceramics is used for a glow plug material, the current control is not performed.

A018109E01


WIRING DIAGRAM


A106787E01


INSPECTION PROCEDURE

1.CHECK GLOW INDICATOR LIGHT
  1. Turn the ignition switch ON.

  1. Check that the glow indicator light comes on.

    OK:
    The glow indicator light remains on for 0.5 sec. or more and then goes off.



NG
Go to step 10
OK


2.INSPECT GLOW PLUG (INSTALLATION)
  1. Check that the glow plug and glow plug wire are securely installed.

    OK:
    The glow plug and glow plug wire are securely installed.



NG
TIGHTEN GLOW PLUG
OK


3.INSPECT GLOW PLUG


    B006785E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    0.72 Ω at 20°C (68°F)

    HINT:
    The higher the temperature is the smaller the resistance becomes and vice versa.



NG
REPLACE GLOW PLUG
OK


4.CHECK FOR INDICATOR LIGHTING TIME AND AFTER GLOW TIME


NG
REPLACE ECM
OK


5.READ OUTPUT DTC
  1. Read the DTC (Click here).

    Result:

    DTC is not output
    A
    DTC is output
    B

SST
09843-18040  


B
GO TO RELEVANT DTC CHART
A


6.INSPECT GLOW PLUG RELAY


    A110561E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    (No continuity)
    3 - 5
    Below 1 Ω
    (Apply B+ between terminals 1 and 2)



NG
REPLACE GLOW PLUG RELAY
OK


7.INSPECT ECM (CHECK VOLTAGE)


    A062416E14
  1. Turn the ignition switch to the START position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Connection
    Specified Condition
    SREL (B10-2) - E1 (D2-14)
    Cranking
    9 to 14 V



NG
REPLACE ECM
OK


8.CHECK HARNESS AND CONNECTOR (ECM - GLOW PLUG RELAY, GLOW PLUG RELAY - BODY GROUND)


    A110551E01
  1. Disconnect the ECM B10 connector.

  1. Disconnect the glow plug relay from the engine room R/B & J/B No.1.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    +S (GLOW relay terminal 2 of R/B) - SREL (B10-2)
    Below 1 Ω
    -S (GLOW relay terminal 1 of R/B) - Body ground
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    SREL (B10-2) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK HARNESS AND CONNECTOR (GLOW PLUG RELAY - GLOW PLUG, GLOW PLUG RELAY - BATTERY)


    A106796E01
  1. Disconnect the battery negative cable.

  1. Disconnect the battery positive cable.

  1. Remove the glow plug relay from the engine room R/B & J/B No. 1.

  1. Disconnect the glow plug wire.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    L (Glow plug relay terminal 3 of R/B) - Glow plug wire
    Below 1 Ω
    B (Glow plug relay terminal 5 of R/B) - Positive terminal of the battery
    Below 1 Ω

    NOTICE:
    After reconnecting the battery cable, the radio and clock should be adjusted as they were previously.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE 

10.INSPECT ECM (CHECK VOLTAGE)


    A062418E01
  1. Disconnect the ECM B8 connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    GIND (B8-1) - E1 (D2-14)
    9 to 14 V



NG
Go to step 11
OK

REPLACE ECM 

11.INSPECT COMBINATION METER (CHECK VOLTAGE)


    A106820E01
  1. Disconnect the combination meter connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    L (H20-25) - Body ground
    9 to 14 V



NG
Go to step 13
OK


12.CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER)


    A106818E01
  1. Disconnect the ECM B8 connector.

  1. Disconnect the combination meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    L (H20-25) - GIND (B8-1)
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK FOR INTERMITTENT PROBLEMS 

13.INSPECT COMBINATION METER (CHECK VOLTAGE)


    A106820E03
  1. Disconnect the combination meter connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    IG+ (H20-6) - Body ground
    9 to 14 V



NG
Go to step 14
OK

REPLACE COMBINATION METER 

14.CHECK FUSE (MET IGN FUSE)


    A106793E01
  1. Remove the MET IGN fuse from the instrument panel J/B.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    MET IGN fuse
    Below 1 Ω (Continuity)



NG
REPLACE FUSE (MET IGN FUSE)
OK


15.CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER, COMBINATION METER - GAUGE FUSE)


    A106821E01
  1. Disconnect the combination meter connector.

  1. Remove the MET IGN fuse from the instrument panel J/B.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    (MET IGN fuse terminal 1 of J/B ) - IG+ (H20-6)
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK AND REPLACE HARNESS AND CONNECTOR (MET IGN FUSE - BATTERY)