Home › BODY › ENGINE HOOD / DOOR › SLIDE DOOR LOCK ASSEMBLY

SLIDE DOOR LOCK ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT POWER SLIDE DOOR LOCK ASSEMBLY RH


    B111204E03
  1. Inspect the door closer motor.

    1. Apply battery voltage and check operation of the slide door closer motor.

      Standard:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 2
      Battery negative (-) → Terminal 1
      Close (Forward)
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 2
      Open (Reverse)



    B111205E03
  1. Inspect the pawl switch and latch switch

    1. Measure the resistance when the switch is operated according to the value(s) in the table below.

      Standard resistance:
      Pawl switch:
      Tester Connection
      Condition
      Specified Condition
      8 - 9
      1. Open
      1. Half latch
      1. Full latch
      10 kΩ or higher
      8 - 9
      Unlatched
      Below 1 Ω
      Latch switch:
      Tester Connection
      Condition
      Specified Condition
      3 - 4, 4- 8
      Open
      Below 1 Ω
      4 - 8
      Half latch
      Below 1 Ω
      3 - 4, 4- 8
      Full latch
      10 kΩ or higher
      -
      Over stroke
      10 kΩ or higher



    B111206E02
  1. Inspect the initial position switch and handle switch.

    1. Measure the resistance when the switch is operated according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      8 - 10
      1. Handle switch ON (Handle initial position)
      1. Initial position switch OFF (Active lever initial position)
      10 kΩ or higher
      8 - 10
      1. Handle switch OFF (As handling)
      1. Initial position switch OFF (Active lever initial position)
      10 kΩ or higher
      8 - 10
      1. Handle switch ON (Handle initial position)
      1. Initial position switch ON (As closer operating)
      Below 1 Ω
      8 - 10
      1. Handle switch OFF (As handling)
      1. Initial position switch ON (As closer operating)
      10 kΩ or higher



2. INSPECT POWER SLIDE DOOR LOCK ASSEMBLY LH


    B111198E02
  1. Inspect the door closer motor.

    1. Apply battery voltage and check operation of the slide door closer motor.

      Standard:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 2
      Battery negative (-) → Terminal 1
      Close (Forward)
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 2
      Open (Reverse)



    B111199E02
  1. Inspect the pawl switch and latch switch

    1. Measure the resistance when the switch is operated according to the value(s) in the table below.

      Standard resistance:
      Pawl switch:
      Tester Connection
      Condition
      Specified Condition
      8 - 9
      1. Open
      1. Half latch
      1. Full latch
      10 kΩ or higher
      8 - 9
      Unlatched
      Below 1 Ω
      Latch switch:
      Tester Connection
      Condition
      Specified Condition
      3 - 4, 4- 8
      Open
      Below 1 Ω
      4 - 8
      Half latch
      Below 1 Ω
      3 - 4, 4- 8
      Full latch
      10 kΩ or higher
      -
      Over stroke
      10 kΩ or higher



    B111203E02
  1. Inspect the initial position switch and handle switch.

    1. Measure the resistance when the switch is operated according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      8 - 10
      1. Handle switch ON (Handle initial position)
      1. Initial position switch OFF (Active lever initial position)
      10 kΩ or higher
      8 - 10
      1. Handle switch OFF (As handling)
      1. Initial position switch OFF (Active lever initial position)
      10 kΩ or higher
      8 - 10
      1. Handle switch ON (Handle initial position)
      1. Initial position switch ON (As closer operating)
      Below 1 Ω
      8 - 10
      1. Handle switch OFF (As handling)
      1. Initial position switch ON (As closer operating)
      10 kΩ or higher