SLIDE DOOR LOCK ASSEMBLY > INSPECTION |
| 1. INSPECT POWER SLIDE DOOR LOCK ASSEMBLY RH |
![]() |
Inspect the door closer motor.
Apply battery voltage and check operation of the slide door closer motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 | Close (Forward) |
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 | Open (Reverse) |
![]() |
Inspect the pawl switch and latch switch
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 8 - 9 |
| 10 kΩ or higher |
| 8 - 9 | Unlatched | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| 3 - 4, 4- 8 | Open | Below 1 Ω |
| 4 - 8 | Half latch | Below 1 Ω |
| 3 - 4, 4- 8 | Full latch | 10 kΩ or higher |
| - | Over stroke | 10 kΩ or higher |
![]() |
Inspect the initial position switch and handle switch.
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 8 - 10 |
| 10 kΩ or higher |
| 8 - 10 |
| 10 kΩ or higher |
| 8 - 10 |
| Below 1 Ω |
| 8 - 10 |
| 10 kΩ or higher |
| 2. INSPECT POWER SLIDE DOOR LOCK ASSEMBLY LH |
![]() |
Inspect the door closer motor.
Apply battery voltage and check operation of the slide door closer motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 | Close (Forward) |
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 | Open (Reverse) |
![]() |
Inspect the pawl switch and latch switch
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 8 - 9 |
| 10 kΩ or higher |
| 8 - 9 | Unlatched | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| 3 - 4, 4- 8 | Open | Below 1 Ω |
| 4 - 8 | Half latch | Below 1 Ω |
| 3 - 4, 4- 8 | Full latch | 10 kΩ or higher |
| - | Over stroke | 10 kΩ or higher |
![]() |
Inspect the initial position switch and handle switch.
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 8 - 10 |
| 10 kΩ or higher |
| 8 - 10 |
| 10 kΩ or higher |
| 8 - 10 |
| Below 1 Ω |
| 8 - 10 |
| 10 kΩ or higher |