CHARGING SYSTEM > ON-VEHICLE INSPECTION |
| 1. CHECK BATTERY CONDITION |
Check the battery for damage and deformation. If severe damage, deformation, or leakage is found, replace the battery.
Check the electrolyte level of each cell.
For maintenance-free batteries:
For non-maintenance-free batteries:
| 2. CHECK BATTERY TERMINAL AND FUSE |
Check that the battery terminals are not loose or corroded.
If the terminals are corroded, clean the terminals.
Measure the resistance of the ALT fuse and ALT-S fuse.
| 3. CHECK V-RIBBED BELT |
![]() |
Check the belt for wear, cracks and other signs of damage.
If any of the following defects is found, replace the drive belt.
![]() |
Check that the belt fits properly in the ribbed grooves.
| 4. VISUALLY CHECK GENERATOR WIRING |
Check that the wiring is in good condition.
| 5. LISTEN FOR ABNORMAL NOISE FROM GENERATOR |
Check that the generator does not emit any abnormal noise while the engine is running.
| 6. CHECK CHARGE WARNING LIGHT CIRCUIT |
Turn the ignition switch to the ON position. Check that the charge warning light comes on.
Start the engine and check that the light goes off. If the light does not operate as specified, troubleshoot the charge warning light circuit.
| 7. CHECK CHARGING CIRCUIT WITHOUT LOAD |
![]() |
Connect a voltmeter and ammeter to the charging circuit as follows:
Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.
Connect the positive (+) lead of the ammeter to terminal B of the generator.
Connect the positive (+) lead of the voltmeter to the positive (+) terminal of the battery.
Ground the negative (-) lead of the voltmeter.
Check the charging circuit.
Keep the engine speed at 2,000 rpm. Check the reading on the ammeter and voltmeter.
| 8. CHECK CHARGING CIRCUIT WITH LOAD |
With the engine running at 2,000 rpm, turn on the high beam headlights and turn the heater blower switch to the HI position.
Check the reading on the ammeter.
| 9. MATRIX FOR EACH PROBLEM SYMPTOM |
Confirm problem symptom.
Confirm the problem symptom and perform inspection by following the corresponding chart.
| Result | Proceed to |
| Problem in charging system (battery is dead and charging light comes on) | Go to step (c) |
| Belt noise and excessive slip | Go to step (g) |
| Noise from generator | Go to next step |
Check lock of the generator with clutch pulley.
Check the function with the pulley installed in the vehicle:
Check the function with the pulley removed from the vehicle:
| Result | Proceed to |
| NG | Replace generator with clutch pulley |
| OK | Repair or replace generator assembly |
Check the V belt for wear.
Check the V belt for wear.
| Result | Proceed to |
| NG | Replace fan and generator V belt |
| OK | Go to next step |
Check the generator with clutch pulley for wear.
Check the generator with clutch pulley groove for wear or other defects.
| Result | Proceed to |
| NG | Replace generator with clutch pulley |
| OK | Go to next step |
Check operation of the one-way clutch.
Check that the generator with clutch pulley (outer ring) turns counterclockwise.
| Result | Proceed to |
| NG | Replace generator with clutch pulley |
| OK | Go to next step |
Check looseness of the generator with clutch pulley.
Start the engine and check looseness of the generator with clutch pulley.
| Result | Proceed to |
| NG | Tighten generator with clutch pulley to the specified torque {110 N*m (1,125 kgf*cm, 81 ft.*lbf)} |
| OK | Check other pulleys |
Check lock of the generator with clutch pulley.
Remove the generator pulley cap. Using SST, fix the generator rotor.
Turn the generator with clutch pulley counterclockwise and check that it locks.
| Result | Proceed to |
| NG | Replace generator with clutch pulley |
| OK | Go to next step |
Check for noise while generator with clutch pulley is operating.
Perform a driving test and check if noise occurs when decelerating.
| Result | Proceed to |
| NG | Replace generator with clutch pulley |
| OK | Repair or replace generator assembly |