CLEARANCE SONAR SYSTEM > Back Sonar Sensor RH Circuit |

| 1.INSPECT NO.2 ULTRASONIC SENSOR |
![]() |
Remove No.2 ultrasonic sensor.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| 1 - 2 | Always | 900 +- 300 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (CLEARANCE WARNING ECU - NO.2 ULTRASONIC SENSOR) |
![]() |
Disconnect the H33 connector from the clearance warning ECU.
![]() |
Disconnect the W3 connector from the No.2 ultrasonic sensor.
Measure the resistance according to the value(s) in the table below.
| Tester connection (Symbols) | Condition | Specified condition |
| H33-5 (S7) - W3-2 (S) | Always | Below 1 Ω |
| H33-18 (E7) - W3-1 (E) | Always | Below 1 Ω |
| H33-5 (S7) - Body ground | Always | 10 kΩ or higher |
| H33-18 (E7) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||