Home › TRANSMISSION · A340E AUTOMATIC TRANSMISSION › ELECTRONIC CONTROLLED AUTOMATIC TRANSMISSION SYSTEM

DTC    P0710/38    Transmission Fluid Temperature Sensor "A" Circuit

DTC    P0712/38    Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC    P0713/38    Transmission Fluid Temperature Sensor "A" Circuit High Input

for Preparation Click here


DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input into the TCM.
G031389E06
The TCM applies a voltage to the temperature sensor through TCM terminal THOC.
The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.
The TCM calculates the fluid temperature based on the voltage signal.

DTC No.
DTC Detection Condition
Trouble Area
P0710/38
  1. (a) and (b) are detected momentarily within 0.5 sec. when neither P0712 nor P0713 is detected (1-trip detection logic)
    1. ATF temperature sensor resistance is less than 79 Ω.
    2. ATF temperature sensor resistance is more than 156 kΩ.

HINT:
Within 0.5 sec., the malfunction switches from (a) to (b) or from (b) to (a)

  1. Open or short in ATF temperature sensor circuit
  2. ATF temperature sensor
  3. TCM
P0712/38
ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic)
  1. Short in ATF temperature sensor circuit
  2. ATF temperature sensor
  3. TCM
P0713/38
ATF temperature sensor resistance is more than 156 kΩ when 15 minutes or more have elapsed after the engine start
DTC is detected for 0.5 sec. or more (1-trip detection logic)
  1. Open in ATF temperature sensor circuit
  2. ATF temperature sensor
  3. TCM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the automatic transmission fluid (ATF) temperature sensor circuit. The automatic transmission fluid (ATF) temperature sensor converts ATF temperature to an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature, and the TCM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the TCM interprets this as a fault in the ATF sensor or wiring. The TCM will turn on the MIL and store the DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:
The ATF temperature can be checked on the Intelligent Tester display.


WIRING DIAGRAM


C109040E01


INSPECTION PROCEDURE


DATA LIST

HINT:
Using the Intelligent Tester Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to shorten labor time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect the Intelligent Tester to the DLC3.

  4. Turn the ignition switch to the ON position.

  5. Turn on the tester.

  6. Select the item "Enter / Power train / ECT / Data List".

  7. Follow the instructions on the tester and read the Data List.

    Item
    Measurement Item /
    Range (display)
    Normal Condition
    A/T Oil Temperature 3
    ATF Temp. Sensor Value/
    min.: -40°C (-40°F)
    max.: 215°C (419°F)
    1. After Stall Test;
      Approx. 80°C (176°F)
    2. Equal to ambient temperature when cold soak

    HINT:
    When DTC P0712 is output and Intelligent Tester output is 150°C (302°F) or more, there is a short circuit.
    When DTC P0713 is output and Intelligent Tester output is -40°C (-40°F), there is an open circuit.
    Measure the resistance between terminal THOC and body ground.

    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150°C (302°F) or more
    Short circuit

    HINT:
    If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 second).

1.INSPECT ATF TEMPERATURE SENSOR


    A111388E01
  1. Disconnect the ATF temperature sensor connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    1 - 2
    79 Ω to 156 kΩ
    1 - Body ground
    10 kΩ or higher
    2 - Body ground
    10 kΩ or higher

    HINT:
    If the resistance is out of the specified range with either the ATF temperature shown in the table below, the driveability of the vehicle may decrease.

    Resistance:
    ATF Temperature
    Specified Condition
    20°C (68°F)
    10.3 to 13.9 kΩ
    110°C (230°F)
    0.68 to 0.88 kΩ



NG
REPLACE ATF TEMPERATURE SENSOR
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)


    F045523E09
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the TCM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    O1-25 (THOC) - O1-23 (E2)
    79 Ω to 156 kΩ

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    O1-25 (THOC) - Body ground
    10 kΩ or higher
    O1-23 (E2) - Body ground
    ↑



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE TCM