INTEGRATION RELAY > INSPECTION |
| 1. INSPECT INTEGRATION RELAY |

![]() |
Measure the resistance of the fan No.3 relay.
Using an ohmmeter, measure the resistance according to the values in the table below.
| Tester Connection | Specified Condition |
| 1I-2 ←→ 1I-3 | Approx 310 Ω |
| 1I-1 ←→ 1I-4 | 10 kΩ or higher |
Connect the battery positive (+) lead to terminal 1I-2 and the negative (-) lead to terminal 1I-3. Using an ohmmeter, measure the resistance according to the value in the table below.
| Tester Connection | Specified Condition |
| 1I-1 ←→ 1I-4 | Below 1 Ω (When battery voltage is applied to terminals 1I-2 and 1I-3) |
![]() |
Measure the resistance of the HORN relay.
Using an ohmmeter, measure the resistance according to the value in the table below.
| Tester Connection | Specified Condition |
| 1I-5 ←→ 1I-7 | Approx 310 Ω |
![]() |
Measure the voltage of the HORN relay.
Disconnect the HAZ-HORN fuse. Connect the battery positive (+) lead to terminal HAZ-HORN fuse 2 (+). Using a voltmeter, measure the voltage according to the values in the table below.
| Tester Connection | Specified Condition |
| 1I-5 ←→ negative battery terminal (-) | battery voltage |
| 1I-8 (+) ←→ negative battery terminal (-) | 0 V |
Connect the battery positive (+) lead to terminal HAZ-HORN fuse 2 (+) and negative (-) lead to terminal 1I-7.Using a voltmeter, measure the voltage according to the value in the table below.
| Tester Connection | Specified Condition |
| 1I-8 (+) ←→ negative battery terminal (-) | battery voltage (When battery voltage is applied to terminals HAZ-HORN fuse 2 (+) and 1I-7) |
![]() |
Measure the resistance of the EFI MAIN relay.
Using an ohmmeter, measure the resistance according to the values in the table below.
| Tester Connection | Specified Condition |
| 1J-2 ←→ 1J-3 | Approx 310 Ω |
| 1J-1 ←→ 1J-4 | 10 kΩ or higher |
Connect the battery positive (+) lead to terminal 1J-2 and negative (-) lead to terminal 1J-3. Using an ohmmeter, measure the resistance according to the value in the table below.
| Tester Connection | Specified Condition |
| 1J-1 ←→ 1J-4 | Below 1 Ω (When battery voltage is applied to terminals 1J-2 and 1J-3) |
![]() |
Measure the resistance of the EDU relay.
Using an ohmmeter, measure the resistance according to the value in the table below.
| Tester Connection | Specified Condition |
| 1J-4 ←→ 1J-7 | Approx 310 Ω |
![]() |
Measure the voltage of the EDU relay.
Connect the battery positive (+) lead to terminal 1J-4.Using a voltmeter, measure the voltage according to the values in the table below.
| Tester Connection | Specified Condition |
| 1J-5 (+) ←→ negative battery terminal (-) | battery voltage |
| 1J-8 (+) ←→ negative battery terminal (-) | 0 V |
Connect the battery positive (+) lead to terminal 1J-4 and battery negative (-) lead to terminal 1J-7.Using a voltmeter, measure the voltage according to the value in the table below.
| Tester Connection | Specified Condition |
| 1J-8 (+) ←→ negative battery terminal (-) | battery voltage (When battery voltage is applied to terminals 1J-4 and 1J-7) |