MASS AIR FLOW METER > INSPECTION |
| 1. INSPECT INTAKE AIR FLOW METER SUB-ASSY |
![]() |
Check the output voltage.
Apply battery voltage across terminals 1 (+B) and 2 (E2G).
Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG) and the negative (-) tester probe to terminal 2 (E2G).
Blow air into the mass air flow meter, then check that the voltage fluctuates.
If the voltage does not fluctuate, replace the mass air flow meter.
![]() |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| Tester Connection | Specified Condition |
| 4 (THA) - 5 (E2) | 12.5 to16.9 kΩ at -20°C (-4°F) |
| 4 (THA) - 5 (E2) | 2.19 to 2.67 kΩ at 20°C (68°F) |
| 4 (THA) - 5 (E2) | 0.50 to 0.68 kΩ at 60°C (140°F) |