Home › BODY ELECTRICAL › DOOR LOCK › UNLOCK WARNING SWITCH

UNLOCK WARNING SWITCH > INSPECTION

for Preparation Click here



1. INSPECT KEY UNLOCK WARNING SWITCH


B112420E01
  1. Remove the key unlock warning switch.

  1. Measure the resistance according to the value in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 2
    Not pushed
    10 kΩ or higher
    1 - 2
    Pushed
    Below 1 Ω

    If the result is not as specified, replace the switch.