Home › TRANSMISSION · A343E AUTOMATIC TRANSMISSION › ELECTRONIC CONTROLLED AUTOMATIC TRANSMISSION SYSTEM

DTC    P2716    Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION

The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor.
The ECM adjusts the duty cycle of the SLT solenoid valve to control hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.
(*): Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then
Duty Ratio = A/(A + B) x 100 (%)
C108924E03

DTC No.
DTC Detection Condition
Trouble Area
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault.
The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM


G031770E09


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SLT)


    C113864E03
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    2 (SLT+) - 6 (SLT-)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Resistance (Check for short):
    Tester Connection
    Specified Condition
    2 (SLT+) - Body ground
    10 kΩ or higher
    6 (SLT-) - Body ground
    ↑



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C095812E17
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    D3-12 (SLT+) - D3-13 (SLT-)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Resistance (Check for short):
    Tester Connection
    Specified Condition
    D3-12 (SLT+) - Body ground
    10 kΩ or higher
    D3-13 (SLT-) - Body ground
    ↑



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE SLT


    G020767E27
  1. Remove the shift solenoid valve (SLT).

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE SLT
OK

REPAIR OR REPLACE TRANSMISSION WIRE