CHARGING SYSTEM > ON-VEHICLE INSPECTION |
| 1. CHECK BATTERY ELECTROLYTE LEVEL |
Check the electrolyte quantity of each cell (Maintenance-Free Battery).
If it is under the low level, replace the battery (or add distilled water if possible) and check the charging system.
Check the electrolyte quantity of each cell (Except Maintenance-Free Battery).
If it is under the low level, add distilled water.
| 2. CHECK BATTERY SPECIFIC GRAVITY (Except Maintenance-Free battery) |
![]() |
Check the specific gravity of each cell.
| 3. CHECK BATTERY VOLTAGE |
If 20 minutes have not elapsed after driving the vehicle or stopping the engine, turn the ignition switch to the ON position and turn on the electrical system (headlight, blower motor, rear defogger etc.) for 60 seconds to remove the surface charge.
Turn the ignition switch off and turn off the electrical systems.
![]() |
Measure battery voltage between the negative (-) and positive (+) terminals of the battery.
![]() |
Check the indicator as shown in the illustration.
| 4. CHECK BATTERY CABLES, FUSIBLE LINK AND FUSES |
Check that the battery cables are not loose or corroded.
Check the fusible link, H-fuses, and fuses for continuity.
| 5. INSPECT DRIVE BELT |
![]() |
Visually check the drive belt for cracks, oiliness, or wear. Check that the belt does not touch the bottom of the pulley groove.
If necessary, replace the drive belts as a set.
| 6. CHECK GENERATOR WIRING |
Check that the wiring is in good condition.
| 7. LISTEN ABNORMAL NOISES FROM GENERATOR |
Check that there is no abnormal noise from the generator while the engine is running.
| 8. INSPECT CHARGE WARNING LIGHT CIRCUIT |
Turn the ignition switch to the ON position. Check that the charge warning light comes on.
Start the engine. Check that the light goes off.
| 9. INSPECT CHARGING CIRCUIT WITHOUT LOAD |
If a battery/generator tester is available, connect the tester to the charging circuit by following the manufacturer's instructions.
If a tester is not available, connect a voltmeter to the charging circuit as follows:
Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.
Connect the positive (+) lead of the ammeter to terminal B of the generator.
Connect the positive (+) lead of the voltmeter to terminal B of the generator.
Ground the negative (-) lead of the voltmeter.
| 10. INSPECT CHARGING CIRCUIT WITH LOAD |
With the engine running at 2,000 rpm, turn on the high beam headlights and tern the heater blower switch to "HI".
Check the reading on the ammeter.